19
EXCALIBUR LINER
English
Clamp released
M3
M1
M2
M6
M4
M5
M
CORRECT PROCEDURE OF DECOMPRESSION
•
Move the switch (
M1
) to the
OFF
(0)
position to stop the
equipment.
•
Unlock the safety clamp (
M3
).
• Point the gun (
M4
) at the receptacle (
M5
) used to collect the
product and press the trigger to release the pressure. When
completed, activate the safety catch again.
WARNING
:
If the equipment is still under pressure after per-
forming the operations above described because
of the nozzle or the flexible hose clogged, proceed
as follows:
• Loosen very slowly the gun nozzle.
• Release the clamp.
• Point the gun at the container of the product
and press the trigger to release pressure.
•
Loosen very slowly the fitting of connection
from the flexible hose to the gun.
• Clean or replace the flexible hose and the
nozzle.
•
Open the recirculating-safety valve(
M6
) to release the remai-
ning pressure.
•
Reduce pressure to the minimum
(turn counterclockwise the
pressure control knob (
M2
))
.