Ediz. 005 - 09/2015
www.larius.eu
DALì LINER PLUS
19
Clamp released
N3
N4
N5
N1
M
CORRECT PROCEDURE OF DECOMPRESSION
• Premere l'interruttore (
N1) su
"OFF"(0) per spegnere l'ap-
parecchiatura.
• Unlock the safety clamp (
N3).
• Point the gun (
N4) at the receptacle (N5) used to collect the
product and press the trigger to release the pressure. When
completed, activate the safety catch again.
WARNING:
If the equipment is still under pressure after per-
forming the operations above described because
of the nozzle or the flexible hose clogged, proceed
as follows:
• Loosen very slowly the gun nozzle.
• Release the clamp.
• Point the gun at the container of the product
and press the trigger to release pressure.
• Loosen very slowly the fitting of connection
from the flexible hose to the gun.
• Clean or replace the flexible hose and the
nozzle.
• Open the recirculating-safety valve (
N6) to release the re-
maining pressure.
•
Ridurre la pressione al minimo
(ruotare in senso antiorario
la manopola di regolazione (N2) della pressione).
N6
N2
OPEN
Summary of Contents for DALI LINER PLUS HAND PUSH