7
OPERATION
7.1 IMPORTANT SAFETY GUIDELINES
FIBROTOR
29
|
50
7
Operation
7.1
Important safety guidelines
Inadmissible operating parameters / software.
The change of the operating parameters leads to a change in the system
behaviour of the rotating or moving parts of the rotary table. The use of a controller
with unlicensed software creates a risk for the safety of the rotary table. The
operating parameters may be changed only by authorised personnel with detailed
knowledge of the modes of operation and the structure of the rotary table. The use
of unlicensed software is prohibited. Violation of this prohibition can lead to serious
injuries.
In the operation of the rotary table it must be ensured that
•
the rotary table is ready for operation and the operating parameters have been
set up correctly.
•
the operating personnel has been informed prior to starting the rotary table
about the correct behaviour in the event of accidents.
•
the operation is performed only by persons who have been trained, instructed
and authorised for that. These persons must know this manual and proceed
according to it.
•
the rotary table is used / deployed only in accordance with its intended use
(see Chapter 1.2 Intendeduse on page 9).
•
during power-up and operation there is no one in the hazard area of the rotary
table.
•
the operating instructions of the operator are observed.
7.2
Workplaces of the operating personnel
The workplaces of the operating personnel are determined by the operator of the
machine.
7.3
Operating modes
The operating modes can be taken from the specification in the annex.
7.4
Functional sequences
7.4.1
Functional sequence of a dividing movement
Prerequisites:
The table top is in any position.
NC control system: Data entry completed
7.4.2
Path of motion
During the dividing procedure by a servo motor the acceleration and deceleration
time must be observed. (NC controlled)
Summary of Contents for FIBRO FIBROTOR VM.NC
Page 1: ...FIBROTOR VM NC TRANSLATION OF THE ORIGINAL ASSEMBLY AND OPERATION MANUAL ...
Page 2: ......
Page 4: ...1 INTRODUCTION 1 1 DEFINITION FIBROTOR 4 50 ...
Page 8: ...1 INTRODUCTION 1 1 DEFINITION FIBROTOR 8 50 ...
Page 14: ...1 INTRODUCTION 1 8 DEFINITIONS OF TERMS FIBROTOR 14 50 ...
Page 28: ...7 OPERATION 6 2 PRIOR TO THE COMMISSIONING FIBROTOR 28 50 ...
Page 30: ...0 7 4 FUNCTIONAL SEQUENCES FIBROTOR 30 50 ...
Page 32: ...9 REPAIR 8 2 CUSTOMER SERVICE FIBROTOR 32 50 ...
Page 36: ...9 REPAIR 9 3 LONG TERM LUBRICATION FIBROTOR 36 50 ...
Page 44: ...13 DECLARATION OF INCORPORATION 13 1 DECLARATION OF INCORPORATION FIBROTOR 44 50 ...
Page 47: ...15 PERSONAL NOTES 15 1 NOTES FIBROTOR 47 50 15 Personal notes 15 1 Notes ...
Page 48: ...15 PERSONAL NOTES 15 1 NOTES FIBROTOR 48 50 ...
Page 50: ......