5: Configuration Using Web Manager
xDirect User Guide
34
Figure 5-8 UDP Connection Settings
Connect Protocol
Datagram Mode
Endpoint Configuration
3. When you are finished, click the
OK
button.
4. On the main menu, click
Apply Settings
.
Protocol
Select
UDP
from the drop-down menu.
Datagram Type
Configures the remote IP or network broadcast address and the remote port.
Enter
01
for directed or broadcast UDP. The default setting is
00
.
Accept Incoming
Select
Yes
to accept incoming UDP datagrams. The default setting is
Yes
.
Local Port
Enter the local port number.
Remote Port
Enter the port number of the remote device.
Remote Host
Enter the IP address of the remote device.
Use Broadcast
Select to broadcast the UDP datagram. Datagrams of type 01 can be sent as
a broadcast by enabling this option. The default is not to broadcast.
Note:
Datagrams are sent as subnet-directed broadcasts.
Device Address Table
The table is enabled when
Datagram Type
is set to
FD
. Enter values
between
1
and
255
to identify units on the local network of device servers.
Note:
Lantronix Tech Support supports Datagram type 01. Datagram Type
FD is for OEM use.