background image

2: Functional Description 

PremierWave® 2050 Through-Hole Adapter Integration Guide 

13 

Pin 

Number 

Signal Name 

Primary Function 

Reset 

State 

Internal 

Pull-up 

/Pull-

down 

Driver 

Strength 

24 

CP11 

Reserved for future GPIO 

 

 

 

25 

RXD2 

UART2 serial receive data input 

 

 

 

26 

SHDN 

Indicates when module is in  

Standby state.  Use to power off  

external devices 

 

 

 

27 

CTS2 

UART2 clear to send input 

 

 

 

28 

CP6_I2CSCL 

Reserved for future GPIO 

 

 

 

29 

CP7 

Reserved for future GPIO 

 

 

 

30 

CP5_I2CDATA  Reserved for future GPIO 

 

 

 

31 

CP9 

Reserved for future GPIO 

 

 

 

32 

5V 

5V power input.  Connect to power plane 

 

 

 

33 

CP10 

Reserved for future GPIO 

 

 

 

34 

5V 

5V power input.  Connect to power plane 

 

 

 

35 

CP8 

Reserved for future GPIO 

 

 

 

36 

5V 

5V power input.  Connect to power plane 

 

 

 

37 

DBTX 

Debug UART  

serial transmit data  

output 

 

 

 

38 

GROUND 

Signal ground.  Connect to ground plane 

 

 

 

39 

GROUND 

Signal ground.  Connect to ground plane 

 

 

 

40 

GROUND 

Signal ground.  Connect to ground plane 

 

 

 

41 

DBRX 

Debug UART serial receive data  

input 

 

 

 

42 

GROUND 

Signal ground.  Connect to ground plane 

 

 

 

 

Note 1:  The logic IO pins are 3.3V tolerant.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for PremierWave 2050

Page 1: ...Part Number 900 787 R Revision A August 2017 PremierWave 2050 Through Hole Adapter Integration Guide...

Page 2: ...takes no obligation to update the information in this publication Lantronix does not make and specifically disclaims all warranties of any kind express implied or otherwise regarding title non infring...

Page 3: ...l on the end product incorporating the PremierWave 2050 module must clearly state that it contains an FCC approved RF module Canada and Japan also require a similar statement For example This product...

Page 4: ...d valid and the FCC ID cannot be used on the final product including the transmitter Changes or modifications to this device not explicitly approved by Lantronix will void the user s authority to oper...

Page 5: ...nctional Description 9 PremierWave 2050 Features__________________________________________________ 9 PremierWave 2050 PW20503 Block Diagram __________________________________ 11 Signal Descriptions __...

Page 6: ...igure 3 5 Evaluation Board Schematic 2 of 6 _________________________________ 26 Figure 3 6 Evaluation Board Schematic 3 of 6 _________________________________ 27 Figure 3 7 Evaluation Board Schematic...

Page 7: ...ion PremierWave 2050 Features Provides an overview of the module functions and mechanical drawing PremierWave 2050 Block Diagram Shows the module functional blocks Signal Descriptions Provides signal...

Page 8: ...all technical and compliance specifications for the module PremierWave 2050 802 11ac Embedded Wi Fi Gateway User Guide Provides information needed to configure use and update the PremierWave 2050 fir...

Page 9: ...ierWave 2050 evaluation kit 802 11ac Embedded Wi Fi Gateway dual U FL Note Please see the PremierWave 2050 802 11ac Embedded Wi Fi Gateway Integration Guide for the LGA footprint variant of the Premie...

Page 10: ...2 Functional Description PremierWave 2050 Through Hole Adapter Integration Guide 10 Figure 2 1 PremierWave 2050 PW20503 Dimensions and Views...

Page 11: ...Through Hole Adapter Integration Guide 11 PremierWave 2050 PW20503 Block Diagram The following drawing is a block diagram of the PremierWave 2050 showing the relationships of the components Figure 2...

Page 12: ...e low to reboot unit 35K PU 2 GROUND Signal ground Connect to ground plane 3 DEFAULT Unit reset to default active low Drive low for 7 seconds or longer to reset unit to default settings 35K PU 4 WAKE...

Page 13: ...served for future GPIO 30 CP5_I2CDATA Reserved for future GPIO 31 CP9 Reserved for future GPIO 32 5V 5V power input Connect to power plane 33 CP10 Reserved for future GPIO 34 5V 5V power input Connect...

Page 14: ...with your certification lab for more details Table 2 3 PremierWave 2050 External Antenna Options Antenna Type Peak Gain Typical Lantronix Part Number Vendor Vendor Part Number Approved Region PCB Str...

Page 15: ...with the PremierWave 2050 For similar PCB strip antennas with longer cables consult with Ethertronics www ethertronics com Lantronix provides a U FL to Reverse SMA antenna cable in with the evaluatio...

Page 16: ...l transceiver in order to connect to external RS232 RS485 or RS422 networks The signals of the Serial Ports may be connected as shown in the reference schematic below The transceiver shown in the refe...

Page 17: ...iver Required PremierWave 2050 Signal DTE Connector DCE Connector Signal Logic Description DB9 DB25 Signal DB9 DB25 Signal RXDx Data In 2 3 RXDx 3 2 TXDx TXDx Data Out 3 2 TXDx 2 3 RXDx RTSx H W Flow...

Page 18: ...ntial pairs on a layer next to the signal ground plane The use of vias on these signals should be minimized Center tap signals RXCT and TXCT should be routed with at least 20 mil trace thickness The a...

Page 19: ...ential pair with ETXP 3 ETXP Ethernet Transmit Positive signal 6 100 ohm differential pair with ETXM 2 RXCT Center tap for receive pair 12 Route 20 mil width 6 TXCT Center tap for transmit pair 10 Rou...

Page 20: ..._LED 22 System status LED active high WLAN_LED 18 LED function for WLAN link indication active low ETH LINK ACT 20 Ethernet link ON Active low Ethernet activity Blink toggle General Purpose I O Pins P...

Page 21: ...when the module is in the shutdown state Use the SHDN signal to gate off external logic when the module is in the shutdown state to minimize power Table 2 10 PremierWave 2050 Reset Signals Signal Pin...

Page 22: ...ion inside of the end unit and installation should be chosen such that the antenna has as clear as possible line of site to the connecting WLAN devices The antenna path should be as clear as possible...

Page 23: ...3 PCB Footprint and Module Dimensions PremierWave 2050 Through Hole Adapter Integration Guide 23 Figure 3 2 PremierWave 2050 PW20503 Module Dimensions...

Page 24: ...re mounting if a The Humidity Indicator Card reads 10 when read at 23 5 C b The MSL3 are not met 4 If baking is required optional condition as below refer to IPC JEDEC J STD 033 a Bake 9 hours 125 C T...

Page 25: ...3 PCB Footprint and Module Dimensions PremierWave 2050 Through Hole Adapter Integration Guide 25 Evaluation Board Schematic Figure 3 4 Evaluation Board Schematic 1 of 6...

Page 26: ...3 PCB Footprint and Module Dimensions PremierWave 2050 Through Hole Adapter Integration Guide 26 Figure 3 5 Evaluation Board Schematic 2 of 6...

Page 27: ...3 PCB Footprint and Module Dimensions PremierWave 2050 Through Hole Adapter Integration Guide 27 Figure 3 6 Evaluation Board Schematic 3 of 6...

Page 28: ...3 PCB Footprint and Module Dimensions PremierWave 2050 Through Hole Adapter Integration Guide 28 Figure 3 7 Evaluation Board Schematic 4 of 6...

Page 29: ...3 PCB Footprint and Module Dimensions PremierWave 2050 Through Hole Adapter Integration Guide 29 Figure 3 8 Evaluation Board Schematic 5 of 6...

Page 30: ...3 PCB Footprint and Module Dimensions PremierWave 2050 Through Hole Adapter Integration Guide 30 Figure 3 9 Evaluation Board Schematic 6 of 6...

Reviews: