Show/Monitor/List Commands
Command Reference
12-106
NDS
Displays NDS error reason counters to help diagnose NDS-related problems.
They are listed in the following table.
TCPIP
Displays detailed counters and status messages specific to the TCP/IP
protocol, including configured nameservers and gateways, the default domain
name, packet information, and ICMP counters.
ICMP messages are sent by TCP/IP nodes in response to errors in TCP/IP
messages or queries from other nodes. The ICMP failure reason counters may
be helpful for detecting specific network problems. They are listed in the
following table.
Examples
Local> SHOW PROTOCOLS APPLETALK ZONES
Table 12-9: NDS Failure Reasons
Bit
NDS Error Reason
0
Success
1
Print server ran out of memory
2
Unexpected response from file server
3
Unexpected response from file server
4
No printers found for the print server
5
No queue found for the printer
6
Login failed.
7
Authentication failed
8
Print server cannot attach to queue
Table 12-10: ICMP Failure Reasons
Bit
ICMP Message Reason
0
ICMP echo message received
1
ICMP echo reply received
2
Destination unavailable—see bits 4-7
3
Unknown ICMP type received
4
Network unreachable, usually from a gateway host
5
Host unreachable
6
Port unreachable, usually from a nameserving error
7
Protocol unreachable
8-15
Unused, should be 0