20 / 26
3.4.10.2 Short description
The TSG extension board for drive is able to activate and move at least two additional drives. It is connected
with the control section of the TSG main board for this purpose. Parameters can be adjusted in the TSG
main board for activating the function (hA), changing the opening and closing time of the drive (h7, hb) and
setting the time delay between the opening of the drive and the opening of the door (hC).
3.4.10.3 Activation of the function
To be able to use the TSG drive expansion board function, activation must be set to
01
with parameter
hA
.
NOTE:
For additional information on parameter settings, see the TSG door control device manual.
3.4.10.4 Opening and closing time of Sinus Drive
The opening and closing time of the Sinus Drive can be adjusted with parameter
h7 and
hb
.
Values can be changed in increments of 0.01 seconds. A time of 0.5 seconds can be applied as the default
value for both the in and out travel of the drive. However, this value must be monitored and adjusted to spe-
cific local conditions as appropriate.
CAUTION:
The values must not be set larger than the time actually required to move the drive in or out.
Otherwise the drive could fail!
NOTE:
When a value is changed and confirmed, it is permanently stored. This means that the modi-
fied value is still available even after a power failure.