background image

Model No:

 GCOF-PPNATFD, GCOD-PT-NAT, GCOF-PT-NAT, GCOF-PTNATMF/CO

 

Commercial  Full Size Gas Convection Oven

PARTS LIST

  

 

 

 

 

 

 

     September 1, 2011 Rev  A

   

 IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED 

 

           

            PAGE

 

          INCLUDE MODEL AND SERIAL NUMBER 

 

 

 

          

 

               

OF

Some items are included for illustrative purposes only and in certain instances may not be available.

 

 

Description

Part

Number

Key

  Number

 

2U-71500-05 

BLOWER WHEEL ECCO/GCCO 

ALL

 

Q9-GCCO-164 

MOTOR MOUNT WELD 

ALL

 

2T-30401-09 

STAT FXD 500 DEG OPEN 

ALL

 

PS-30200-35 

REPLACEMENT MOTOR 

ALL

 

Q9-GCCO-181 

BODY BACK 

ALL

 

Q9-GCCO-264-1 

FLUE DEFLECTOR SPOT 

ALL

 

LM-GCCO-154 

CAN TOP ASSY 

GCOF

 

 

Q9-60102-1403 

GCCO TOP PANEL ASSY w/ MNT HRD 

GCOD

 

Q9-60102-140 

GCCO RIGHT SIDE S/S 

GCOF

 

 

Q9-60102-1402 

GCCO RIGHT SIDE S/S EXTRA DEEP w/ MNT HRD  GCOD

 

2E-31107-02 

CORD SET 14/3 X 8’ 15A  

ALL

 

10 

Q9-60102-171 

 

GCCO COOLING FAN KIT 120V 

 

 

Q9-60102-1711 

 

GCCO COOLING FAN KIT 220V 

 

11 

Q9-60102-904 

ACCESS COVER - ECCO/GCCO, & HRDWR 

ALL

 

12 

Q9-GCCOPPP 

PANEL GCCO PURPLE PLUS 

GCOF-PPNATFD

 

 

Q9-GCCOPPT 

PANEL GCCO PLATINUM 

GCOD-PT-NAT, GCOF-PT-NAT,  

 

 

 

 

 

GCOF-PTNATMF

 

13 

2A-50312-01 

DOOR CHAIN 

ALL

 

 

Q9-50312-02 

DOOR CHAIN AND TURNBCKL ASSY 

ALL

 

14 

2P-73000-03 

SST SPRKT40B11 5/8 BORE 

ALL

 

15 

Q9-ECCO-145-1 

MICRO SWITCH BRACKET 

ALL

 

16 

2E-30301-02 

SWITCH, MICRO 

ALL

 

17 

Q9-GCCO-257-W1 

BURNER WELD ASSY 

ALL

 

18 

2E-41100-08 

SENSOR ECCO/GCCO TEMP 

ALL

 

19 

Q9-60102-115 

 

BOTTOM PANEL WELD ASSY w/ LOGO 

ALL

 

20 

Q9-GCCO-233-2 

BOTTOM PANEL ASSY  

ALL

 

21 

2M-60301-43 

DIE CAST PLT LANG SATIN 

ALL

 

22 

2B-50200-20 

RACK ECCO/GCCO OVEN 

GCOF

 

 

2B-50200-31 

RACK ECO DEEP OVEN ONLY 

GCOD

 

23 

2B-50200-33 

RACK SLIDE 5 POS ECO DEEP 

GCOD

 

 

2B-50200-93 

RACK SLIDE 11 POS 

GCOF

 

24 

2E-31602-04 

LAMP SKT SNAP-IN WHT 

ALL

 

25 

2S-31603-09 

LAMPS INC 120V 40W 

ALL

 

26 

Q9-60102-137 

BODY SIDE LH GCCO 

GCOF

 

 

M9-60102-14021 

GCCO LEFT SIE S/S EXTRA DEEP w/ MNT HRD 

GCOD

 

27 

Q9-50312-44 

LH DOOR ASSY E/GCCO 

ALL

 

 

Q9-50312-441 

LH DOOR ASSY E/GCCO SOLID 

GCOFSD

 

28 

Y9-50312-05 

HANDLE ASSY 1 HANDLE 

ALL

 

29 

Q9-50312-47 

LH OUTER DOOR 

ALL

 

30 

2Q-71301-04 

WINDOW ASSY 9-5/8X16-5/8 

ALL

 

31 

Q9-50312-54 

LH INNER DOOR 

ALL

 

32 

Q9-50312-43 

RH DOOR ASSY E/GCCO 

ALL

 

 

Q9-50312-431 

RH DOOR ASSY E/GCCO SOLID 

GCOFSD

 

33 

Q9-GCCO-161 

SNORKEL ASSY 

ALL

 

34 

Q9-GCCO-224-2 

BAFFLE REAR ASS 

ALL

 

NI 

2A-80400-01 

ORIFICE SPUD UNDRILLED 

GCOD-NAT

 

NI 

Y9-80400-14 

ORIFICE SPUD .0595 #53 

GCOD-NAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Qty 
Per

Summary of Contents for GCOF-PP-NAT

Page 1: ...ternational 10 Sunnen Drive St Louis MO 63143 3800 Part Number 2M W740 Ph 314 781 2777 Fax 314 781 2714 Rev A WWW STAR MFG COM November 5 2009 Installation Operation Maintenance and Service Instructio...

Page 2: ...OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE POST IN A PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS THIS INFORMAT...

Page 3: ...Contents Chapter Page Table Of Contents 3 Read First 4 Equipment Description 6 Unpacking 7 Installation 8 Initial Start Up 13 Operation 14 Maintenance Cleaning Procedures 18 Troubleshooting 19 Parts...

Page 4: ...ational State and locally recognized installation standards WARNING THIS APPLIANCE IS EQUIPPED WITH A 3 PRONG GROUNDING PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND MUST BE PLUGGED DIRECTLY INTO...

Page 5: ...y Consult your Lang Authorized Service Agent Directory You can call our toll free number 1 800 807 9054 or visit our website WWW STAR MFG COM for the service agent nearest you WARNING BOTH HIGH AND LO...

Page 6: ...f porcelainized stainless steel Operation The GCOF PPNATFD oven is a forced air convection oven with a vented oven cavity The air is driven by a 1 3 HP fan motor Controls Complete computerized control...

Page 7: ...r to un crating move the oven as near to its intended location as practical The crating will help protect the unit from the physical damage normally associated with moving it through hallways and door...

Page 8: ...provided in the leg kit Lift the oven onto its front legs and block the back up using one of the 27 inch legs set upside down in the center rear of the oven body Install the last 27 inch leg onto the...

Page 9: ...and the adapter holes labeled B then install 5 16 inch nuts with lock washers and flat washers Adapter to Oven Installation Gently tip the oven onto its back Place the front leg adapter into the fron...

Page 10: ...combustion or ventilation air The installation of any components such as a vent hood grease extractors and or fire extinguisher systems must conform to the there applicable nationally recognized inst...

Page 11: ...10 inch water column for propane A 1 8 inch NPT tap is provided on the main manifold for checking regulator pressure Access the main manifold by removing the trim piece below the oven doors When repla...

Page 12: ...ch 3 8 aluminum pipe to black manifold assembly 16 Remove the seal screw from the combination gas valve 17 Remove the adjustment screw and spring from the combination valve 18 Insert new spring into t...

Page 13: ...oven power switch is turned On the pilot will light There is a lockout safety feature on the spark ignition module If during the initial start up the pilot does not light within 30 seconds the module...

Page 14: ...ff position AlphaNumeric Display Shelf Select Button Press to select shelf which product will be placed Product Select Button Press to select desired product Manual Program Button Use when product bei...

Page 15: ...again Beeper sounds briefly and display says SELECT OVEN SHELVES PRODUCT X Press the shelf button s which correspond to the shelf positions which the product is loaded A equals the top shelf and E eq...

Page 16: ...ll give you a more consistent size color and quality Check the product near the end of the initial cooking cycle by turning on the oven light and looking through the oven door windows Do not open the...

Page 17: ...e parchment does not blow over the product The will create a uneven bake Load each shelf evenly Spaces should be maintained equally between the pan and oven walls front and back Do not overload pan s...

Page 18: ...utes Longer contact can cause corrosion Cleaning Always start with a cold oven The stainless exterior can easily be cleaned using stainless steel cleaner Always follow the cleaner manufacturer s instr...

Page 19: ...nplugged from outlet Failed power cord or plug Failed power switch Failed pilot ignition Contrast needs to be adjusted Failed display board Oven will not heat Power Switch is not ON No product selecte...

Page 20: ...ck probe for proper resistance Failed Circuit Board Confirm that board is getting correct voltage Confirm that board is putting out correct voltage Failed Valve Remove the wires and check for continui...

Page 21: ...32 3 6 25 24 27 31 30 29 28 23 22 26 21 19 SEE DETAIL A SEE DETAIL B SEE DETAIL C SK2348 Rev A 1 31 11 Model 1 2 4 5 8 7 9 10 11 14 15 16 17 13 12 20 18 34 33 GCOD F PP GCOD F PT Gas Covection Oven...

Page 22: ...3 2A 50312 01 2 DOOR CHAIN ALL Q9 50312 02 2 DOOR CHAIN AND TURNBCKL ASSY ALL 14 2P 73000 03 1 SST SPRKT40B11 5 8 BORE ALL 15 Q9 ECCO 145 1 1 MICRO SWITCH BRACKET ALL 16 2E 30301 02 1 SWITCH MICRO ALL...

Page 23: ...Kit Assy Manifold Assembly SK2310 Rev C 12 1 10 Model GCOD F NAT GCOD F LP Detail A Gas Covection Oven Pilot Manifold Assy Detail B GCCO Cooling Fan Kit Assy 1 2 5 6 7 Available in Assembly only 14 16...

Page 24: ...8 inch SLEEVING TEFLON 1 4X 030 ALL 11 2I 70803 04 6 CERMC INSLTR 9 32ID11 16 ALL 12 Q9 GCCO 706 1 MANIFOLD ASSY NAT Q9 GCCO 706 WP 1 MANIFOLD ASSY LP 13 2K 70308 01 1 PIPE PLUG REG 1 8 NPT BLK ALL 14...

Page 25: ...2 9 4 19 21 23 3 22 20 4 13 14 16 17 2 18 16 15 12 26 24 25 24 29 30 29 31 32 35 34 33 26 27 28 27 28 8 2 4 SK2346 Rev 2 1 08 Model GCCOPPP Purple Plus GCCOPPT Platinum Full Size Gas Control Panels A...

Page 26: ...30402 27 1 STAT ADJ 450 DEG 48 PILOT GCCOPPT GCCOPPP 15 Q9 GCCO 223 7 1 SWITCH INSULATOR GCCOPPT GCCOPPP 16 2E 30303 06 2 SWT TOG ON ON DPDT BLK GCCOPPP 17 Q9 GCCO 223 8 1 AUXILLARY STAT MOUNT GCCOPP...

Page 27: ...UL File MH19366 22 Wiring Diagram 120 Volt...

Page 28: ...UL File MH19366 23 WIRING DIAGRAM 220 240 Volt...

Reviews: