UL File# MH19366
13
Initial Start Up
WARNING
BEFORE LIGHTING, USE A SOAP AND WATER SOLUTION TO TEST ALL
JOINTS FOR GAS LEAKS.
Pre-Power On
After the oven is installed and connected to power & gas, prior to turning on,
verify the following:
The doors open and close freely.
All racks are in the oven correctly.
All packing materials have been removed from the inside of the
oven. All power and gas connections are tight
Power On
The pilot burner is electronically ignited. When the oven power switch is
turned On the pilot will light.
There is a lockout safety feature on the spark ignition module. If, during the
initial start-up, the pilot does not light within 30 seconds the module will turn
off all gas to the pilot burner. To reset the spark module, turn Off the power
switch for 10 seconds then turn the switch back On. This may need to be
repeated several times during the initial start-up until gas is present at the
pilot burner.
NOTICE
During the first few hours of operation you may notice a small amount of
smoke coming off the oven, and a faint odor from the smoke. This is
normal for a new oven and will disappear after the first few hours of use.