background image

2M-W363: Electric Clamshell® CSE12A

5

GENERAL INFORMATION continued

Technical

The broiler, not including the griddle, is standard 208 or 240V, single phase. Specify voltage when ordering.

Receiving the Unit

Upon receipt, check for freight damage, both visible and concealed. Note visible damage 

on the freight bill at the time of delivery and have the carrier’s agent sign the freight bill 

at that time. Concealed loss or damage means loss or damage, which does not become 

apparent until the merchandise has been unpacked. Make a written request for inspection 

upon unpacking and finding concealed damage within 15 days of delivery. Keep all packing 

material for inspection.  Do not return damaged merchandise to Lang Manufacturing.  

File your claim with the carrier.

Location

Prior to un-crating, move the unit as near its intended location as practical.  The crating will help protect the unit from 

the physical damage normally associated with moving it through hallways and doorways.

Un-crating

The unit will arrive completely assembled inside a wood frame covered by cardboard box and strapped 

to a skid. Remove the cardboard cover, cut the straps and remove the wood frame.

THE UNIT IS EXTREMELY HEAVY.  FOR SAFE HANDLING, INSTALLER SHOULD OBTAIN 

HELP AS NEEDED OR EMPLOY APPROPRIATE MATERIALS-HANDLING EQUIPMENT 

(SUCH AS A FORKLIFT, DOLLY OR PALLET JACK) TO REMOVE THE UNIT FROM THE SKID 

AND MOVE IT TO THE PLACE OF INSTALLATION.
ANY STAND, COUNTER OR OTHER DEVICE ON WHICH THE UNIT WILL BE LOCATED MUST 

BE DESIGNED TO SUPPORT THE WEIGHT OF THE UNIT.

SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.

Remove unit from the skid.

CAUTION

NOTICE

Summary of Contents for Electric Clamshell CSE12-208VCD

Page 1: ...ELECTRIC CLAMSHELL CSE12 208VCD CSE12A 1 CSE12A 2 Glass Surface CSE12A 1G thru CSE12A 6G Contact Clam CCSE12A 208 Installation and Operation Instructions 2M W363 Rev F 3 19 2015 CSE12A...

Page 2: ...BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY NOTICE Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability Lang reserves the right to change specifica...

Page 3: ...List CSE12 208VCD CSE12A 1 CSE12A 2 12 13 CSE12A 1G thru 6G glass surface 14 15 CSE12 CC208 contact clam 16 18 Wiring Diagram CCSE12A1 contact clam 19 CSE12A 20 PROBLEMS QUESTIONS or CONCERNS Before...

Page 4: ...eaning inspection and maintenance must be established and comprehensive maintenance records maintained It is the sole responsibility of the user to establish schedule and enforce the frequency and sco...

Page 5: ...ing File your claim with the carrier Location Prior to un crating move the unit as near its intended location as practical The crating will help protect the unit from the physical damage normally asso...

Page 6: ...CAUSE INJURY TO PERSONNEL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WIHT ALL APPLICABLE CODES BROILER ELEMENTS CAN IGNITE GREASE FIRES ON THE GRIDDLE SURFACE WHICH MAY RESULT IN...

Page 7: ...and place the hood into the down position Allow the unit to saturate until all vapor and condensation have been removed For best operating results allow the unit to thoroughly dry out for 8 to 12 hour...

Page 8: ...s Cooktop Cleaner directions for cleaner must be followed CHROME SURFACES certain models It takes very little time and effort to keep this Industrial Chrome griddle surface sparkling clean and perform...

Page 9: ...mplishing this please call a qualifi ed service agent or Star Manufacturing Technical Service Department 1 Remove the front bolts from the hood stop and loosen the back bolts up do not completely remo...

Page 10: ...ctual temperature press and hold Temp Button Display will read Lo F if temperature is below 273 F 134 C and Hi F if temperature is above 573 F 301 C To Program Time and Temperature 1 Press and hold TE...

Page 11: ...2M W363 Electric Clamshell CSE12A 11...

Page 12: ...2M W363 Electric Clamshell CSE12A 12 Parts List ETL File 68964 Rev A2007 11 Parts List...

Page 13: ...LL 10 2K 70801 04 SNAP BUSH 3 4 SB750 10 1 ALL 11 K9 EZG 418 1 OUTER BOX SPOTWELD CSE12 1 ALL 12 K9 EZG 429 SPOT CONNECTOR MOUNT 1 ALL 13 K9 EZG 430 BOX HEAT SHIELD COMBO 1 ALL 14 K9 EZG 433 BOX HEAT...

Page 14: ...lectric Clamshell CSE12A 14 SK2522 Rev 6 15 2011 Model CSE12A 1G thru CSE12A 6G CLAMSHELL HOOD GLASS Purchase these items together 1 2 3 1 25 26 27 22 23 24 4 5 7 8 9 1 13 15 1 19 20 21 16 17 14 12 11...

Page 15: ...LEMENT CLAMP 1 13 2C 20301 11 NUT HEX 8 32 PLTD 2 14 2C 20202 12 WSHR LOCK 8 INT STAR 2 15 K9 XLH 742 1 MERCURY SWITCH BRACKET 1 16 K9 XLH 741 1 MERCURY SWITCH BASE 1 17 2C 20101 28 SCRW THD MS 8 32X3...

Page 16: ...2M W363 Electric Clamshell CSE12A 16 SK2742 Rev 02 10 14 Model CCSE12A1 Contact Clam See Detail A 1 5 6 7 8 9 10 11 12 13 14 15 16 2 3 17 4...

Page 17: ...XLH 762 1 1 RIGHT HINGE ARM PIVOT ASY 7 K9 XLH 721 4 1 PIVOT ASSY CCSE12 8 K9 XLH 644 2 PISTON ROD TUBE SLEEVE 9 K9 XLH 813 1 SPRING BAFFLE 10 2N 11060 30 1 ELEMENT 208V 3600W 11 K9 XLH 820 1 CC WELD...

Page 18: ...s CONDUIT TUBNG 1 2FLEX sold by the inch 5 K9 XLH 580 4 1 CONTROL BOX BACK ASSY 6 2E Z3335 1 RELAY DBL POLE SNGL THROW 7 2C 20301 10 4 NUT HEX 6 32 PLTD 8 2E 05 07 0350 1 TRANSFORMER 230V 10V 6VA 9 2E...

Page 19: ...ORMATION CONFIDENTIAL TO STAR MFG INT L INC NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED ST LOUIS MO 63143 USA 10 SUNNEN DRIVE TDV 10 25 13 CCSE12A CONTACT CLAM W D 61113 W38 RELAY CONTA...

Page 20: ...2M W363 Electric Clamshell CSE12A 20...