background image

2M-W363: Electric Clamshell® CSE12A

10

OPERATING INSTRUCTIONS 

CONTACT CLAM ONLY

1.  Turn unit on by placing switch in "ON" position.  The "Heat On" indicator, program number and display will flash 

indicating unit is heating.  When the preset temperature is reached, the heating light, display and program light 

indicator will stop flashing followed by 3 beeps.  (Initial startup heating time is approximately 30 minutes).

2.  Place product on the bottom cooking surface of the unit and close the lids.
3.  Press program button and let displayed time count down to "0" at which time unit will beep.   

To turn off the beeper, press program button again.

4.  Raise lids until it engages into first indent and remove food.  Using spatula, scrape residue into grease catcher 

tray.

5.  Turn the unit off when not in use.

TEMPERATURE/TIMER CONTROLLER OPERATION SPECIFICATIONS
Startup:

1.  The preset time will flash until preset temperature is reached.
2.  When the control reaches preset temperature, time display, "Heat On" indicator and program indicator will stop 

flashing and the alarm will beep three times.

Temperature:

1.  To view the actual temperature, press and hold "Temp Button."  Display will read "Lo F" if temperature is below 

273°F (134°C) and "Hi F" if temperature is above 573°F (301°C).

To Program Time and Temperature:

1.  Press and hold "TEMP" (actual temperature displays).
2.  While holding "TEMP," press and hold any program button on the Left one second, the LED above the program 

number light and the display reads "_ _ _ _."  Enter the four-digit security code sequence, 4, 3, 2, 1. The security 

code will not show on the display.  Once the correct sequence has been entered, the preset time will be displayed 

and the LED for that program will begin to flash.

3.  Set the time with the "+ or -" buttons.
4.  Press the "TEMP" button to save the time.
5.  The preset temperature will now be displayed.  
6.  Set the desired temperature for this program using the "+ or -" buttons.
7.  Press the "TEMP" button to save temperature and to exit programming mode for this program.  The LED will 

stop flashing but will remain lit.

8.  Press any other program button within 15 seconds to continue programming without re-entering the security 

code.

9.  While programming a program (LED is flashing), if no input is received for 15 seconds, the unit will revert to 

normal operation and the security code must be re-entered.

Note: Each programming change must be saved by pressing the "TEMP" button!

Summary of Contents for Electric Clamshell CSE12-208VCD

Page 1: ...ELECTRIC CLAMSHELL CSE12 208VCD CSE12A 1 CSE12A 2 Glass Surface CSE12A 1G thru CSE12A 6G Contact Clam CCSE12A 208 Installation and Operation Instructions 2M W363 Rev F 3 19 2015 CSE12A...

Page 2: ...BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY NOTICE Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability Lang reserves the right to change specifica...

Page 3: ...List CSE12 208VCD CSE12A 1 CSE12A 2 12 13 CSE12A 1G thru 6G glass surface 14 15 CSE12 CC208 contact clam 16 18 Wiring Diagram CCSE12A1 contact clam 19 CSE12A 20 PROBLEMS QUESTIONS or CONCERNS Before...

Page 4: ...eaning inspection and maintenance must be established and comprehensive maintenance records maintained It is the sole responsibility of the user to establish schedule and enforce the frequency and sco...

Page 5: ...ing File your claim with the carrier Location Prior to un crating move the unit as near its intended location as practical The crating will help protect the unit from the physical damage normally asso...

Page 6: ...CAUSE INJURY TO PERSONNEL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WIHT ALL APPLICABLE CODES BROILER ELEMENTS CAN IGNITE GREASE FIRES ON THE GRIDDLE SURFACE WHICH MAY RESULT IN...

Page 7: ...and place the hood into the down position Allow the unit to saturate until all vapor and condensation have been removed For best operating results allow the unit to thoroughly dry out for 8 to 12 hour...

Page 8: ...s Cooktop Cleaner directions for cleaner must be followed CHROME SURFACES certain models It takes very little time and effort to keep this Industrial Chrome griddle surface sparkling clean and perform...

Page 9: ...mplishing this please call a qualifi ed service agent or Star Manufacturing Technical Service Department 1 Remove the front bolts from the hood stop and loosen the back bolts up do not completely remo...

Page 10: ...ctual temperature press and hold Temp Button Display will read Lo F if temperature is below 273 F 134 C and Hi F if temperature is above 573 F 301 C To Program Time and Temperature 1 Press and hold TE...

Page 11: ...2M W363 Electric Clamshell CSE12A 11...

Page 12: ...2M W363 Electric Clamshell CSE12A 12 Parts List ETL File 68964 Rev A2007 11 Parts List...

Page 13: ...LL 10 2K 70801 04 SNAP BUSH 3 4 SB750 10 1 ALL 11 K9 EZG 418 1 OUTER BOX SPOTWELD CSE12 1 ALL 12 K9 EZG 429 SPOT CONNECTOR MOUNT 1 ALL 13 K9 EZG 430 BOX HEAT SHIELD COMBO 1 ALL 14 K9 EZG 433 BOX HEAT...

Page 14: ...lectric Clamshell CSE12A 14 SK2522 Rev 6 15 2011 Model CSE12A 1G thru CSE12A 6G CLAMSHELL HOOD GLASS Purchase these items together 1 2 3 1 25 26 27 22 23 24 4 5 7 8 9 1 13 15 1 19 20 21 16 17 14 12 11...

Page 15: ...LEMENT CLAMP 1 13 2C 20301 11 NUT HEX 8 32 PLTD 2 14 2C 20202 12 WSHR LOCK 8 INT STAR 2 15 K9 XLH 742 1 MERCURY SWITCH BRACKET 1 16 K9 XLH 741 1 MERCURY SWITCH BASE 1 17 2C 20101 28 SCRW THD MS 8 32X3...

Page 16: ...2M W363 Electric Clamshell CSE12A 16 SK2742 Rev 02 10 14 Model CCSE12A1 Contact Clam See Detail A 1 5 6 7 8 9 10 11 12 13 14 15 16 2 3 17 4...

Page 17: ...XLH 762 1 1 RIGHT HINGE ARM PIVOT ASY 7 K9 XLH 721 4 1 PIVOT ASSY CCSE12 8 K9 XLH 644 2 PISTON ROD TUBE SLEEVE 9 K9 XLH 813 1 SPRING BAFFLE 10 2N 11060 30 1 ELEMENT 208V 3600W 11 K9 XLH 820 1 CC WELD...

Page 18: ...s CONDUIT TUBNG 1 2FLEX sold by the inch 5 K9 XLH 580 4 1 CONTROL BOX BACK ASSY 6 2E Z3335 1 RELAY DBL POLE SNGL THROW 7 2C 20301 10 4 NUT HEX 6 32 PLTD 8 2E 05 07 0350 1 TRANSFORMER 230V 10V 6VA 9 2E...

Page 19: ...ORMATION CONFIDENTIAL TO STAR MFG INT L INC NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED ST LOUIS MO 63143 USA 10 SUNNEN DRIVE TDV 10 25 13 CCSE12A CONTACT CLAM W D 61113 W38 RELAY CONTA...

Page 20: ...2M W363 Electric Clamshell CSE12A 20...

Reviews: