4.6
Protective Cover
The BIOGAS 3000 has a protective cover fitted inside the main enclosure to
cover areas where mains voltages are present. This cover must be removed in
order to wire the mains supply to the BIOGAS 3000 system and to replace
fuses.
Warning
The cover must only be removed when power to the
system has been isolated. Failure to isolate the power
before removing the cover could result in an electric
shock.
It is vital that after installation and prior to powering the
equipment that the protective cover is replaced. Failure
to replace the cover could result in an electric shock.
The cover is removed by unscrewing four M6 x 12mm button head screws with
a 4mm hexagon tool (see
Figure 6 - Mains cover removal
). The cover and
screws must be kept safe once removed to ensure that they are not lost and
can be refitted once installation is complete.
To fit the cover, simply align the holes in the protective cover with the four
pillars fixed to the BIOGAS 3000 back plate and screw in to place using the
4mm hexagon tool.
Note: For clarity, some images of the BIOGAS 3000 system in this
operating manual may not include the protective cover.