1 800 - LANDICE | [email protected] | WWW.LANDICE.COM
Measuring AC & DC Amperage
AC
Amperage must be perform on the
BROWN WIRE
of the linecord.
DC
Amperage must be perform on the
RED WIRE
from the drive motor.
While straddling the belt, start the treadmill and bring the speed up to
3.0
mph at
0%
elevation. Once the treadmill is up to speed start walking on the treadmill while looking at the
voltmeter. The voltmeter will start giving you an amperage reading. The average highest
reading possible equals your amperage reading. The more friction, the hotter the treadbelt
will become which will increase your amperage reading.
AC Amperage DC Amperage Treadbelt Condition
2.0-4.0 AC Amps
4.5-6.0 DC Amps
Good
5.0-7.0 AC Amps
7.0-9.0 DC Amps
Normal
7.0-10.0 AC Amps
9.0-12.0 DC Amps
Replace
Adc Indicates DC Amperage
Aac Indicates AC Amperage
AMP METER CLAMP
USE THE CHART BELOW TO DETERMINE THE TREADBELT CONDITION
PERFORMING AMPERAGE INSTRUCTIONS
Summary of Contents for M1
Page 1: ...1 800 LANDICE SERVICE LANDICE COM WWW LANDICE COM M1 Folding Treadmill Service Manual ...
Page 10: ...1 800 LANDICE SERVICE LANDICE COM WWW LANDICE COM Electrical Schematic ...
Page 24: ...1 800 LANDICE SERVICE LANDICE COM WWW LANDICE COM Flowchart No Power ...
Page 25: ...1 800 LANDICE SERVICE LANDICE COM WWW LANDICE COM Flowchart ERR 02 ERR 03 OIL Error ...
Page 26: ...1 800 LANDICE SERVICE LANDICE COM WWW LANDICE COM Exploded Parts View ...