19
Maintenance
PROBLEM
POSSIBLE CAUSE
SOLUTION
BURNER WILL
NOT LIGHT
(continued from
previous page)
Improper electrode setting
Check and reset according to diagram in Operator’s
Manual.
Fuel not reaching combustion
chamber
Check fuel pump for proper flow. Check solenoid flow
switch on machines with spray gun control, for proper
on-off fuel flow control.
Clogged burner nozzle
Clean as required.
Thermostat faulty or slow
engine speed
Increase engine RPM to increase voltage.
Flow switch malfunction
Remove, test for continuity and replace as needed.
Flow solenoid malfunction
Replace if needed.
FLUCTUATING
PRESSURE
Valves worn
Check and replace if necessary.
Blockage in valve
Check and replace if necessary.
Pump sucking air
Check water supply and air seepage at joints in
suction line.
Worn piston packing
Check and replace if necessary.
Engine altitude
The engine is preset for operation at altitudes below
1000 feet above sea level. If operated at higher alti-
tudes, it may be necessary to contact your local
authorized engine sales and service center for details.
MACHINE
SMOKES WHILE
BURNER UNIT IS
RUNNING OR
UNIT SMOKES AT
COLD-START
ONLY WHEN
BURNER IS OFF
Improper fuel or water in fuel
Drain tank and replace contaminated fuel.
Improper air adjustment
Readjust air bands on burner assembly.
Fuel pressure is low <140 psi for
burner
Adjust fuel pump pressure to specifications.
Plugged or dirty burner nozzle
Replace nozzle Check parts breakdown for nozzle
size.
Faulty burner nozzle spray pattern
Replace nozzle Check parts breakdown for nozzle
size
Coil and burner assembly have
heavy accumulation of soot
Remove coils and burner assembly, clean thoroughly
Call local dealer.
Misaligned electrode setting
Realign electrodes to specifications.
Smoke stack has obstruction
Check for insulation blockage or other foreign objects.
Engine RPM is low
Increase RPM to correct specs. See serial plate.
Fuel Pressure is too high for clean
burn (fuel PSI above >140 and
below 200) and smokes when
burner is off
Reduce fuel pressure PSI/Increase air band set for
cleaner without max water heat loss
Landa PDHW Series Operator’s Manual 8.919-980.0 - B