background image

5

Safety

Introduction & Safety Information

Thank you for purchasing a Landa Heater Module.
This manual covers the operation and maintenance of 

the NG-3000 heater module. All information in this 

manual is based on the latest product information 

available at the time of printing.
Landa, Inc. reserves the right to make changes at any 

time without incurring any obligation.

Owner/User Responsibility:

The owner and/or user must have an understanding of 

the manufacturer’s operating instructions and warnings 

before using this pressure washer. Warning information 

should be emphasized and understood. If the operator 

is not fluent in English, the manufacturer’s instructions 

and warnings shall be read to and discussed with the 

operator in the operator’s native language by the 

purchaser/owner, making sure that the operator 

comprehends its contents.
Owner and/or user must study and maintain for future 

reference the manufacturers’ instructions.
The operator must know how to stop the machine 

quickly and understand the operation of all controls. 

Never permit anyone to operate the engine without 

proper instructions.

SAVE THESE INSTRUCTIONS

This manual should be considered a permanent part of 

the machine and should remain with it if machine is 

resold.
When ordering parts, please specify model and

 

serial number. Use only identical replacement parts.
This machine is to be used only by trained 

 

operators.

Important Safety Information

NOTE: This heater module NG-3000 is designed 

for connection to a pressure washer (not 

included). Read and follow WARNING and 

operating instructions of pressure washer 

connected to model NG-3000.

WARNING: To reduce the risk of 

injury, read operating instructions 

carefully before using.
AVERTISSEMENT: Pour réduire le 

risque de blessures, lire attentive

-

ment les instructions de 

fonctionnement avant l'utilisation.

1. Read the owner's manual thor

-

oughly. Failure to follow instruc

-

tions could cause malfunction of the machine and 

result in death, serious bodily injury and/or property 

damage.

2. Know how to stop the machine and bleed pressure 

quickly. Be thoroughly familiar with the controls.

3. Stay alert — watch what you are doing.
4. Do not replace LP tank while machine is running.
5. All installations must comply with local codes. 

Contact your electrician, plumber, utility company 

or the selling dealer for specific details. If your 

machine is rated 250 volts or less, single phase a 

ground fault circuit interrupter (GFCI) will be 

provided. If rated more than 250 volts, or more 

than single phase this product should only be 

connected to a power supply protected by a GFCI.

Landa NG 3000 Operator’s Manual  8.913-942.0 - E

WARNING

    READ OPERATOR’S 

 MANUAL THOROUGHLY 

           PRIOR TO USE.

OPERATIONS

SAFET

Y

MAINTENANCE

Summary of Contents for NG-3000

Page 1: ...8 913 942 0 E 08 20 21 NG Hot Water Generator Operator s Manual Heater Module MODELS NG 3000 1 103 901 0 For the Landa Dealer nearest you consult our web page at www landa com...

Page 2: ...2 Landa NG 3000 Operator s Manual 8 913 942 0 E Machine Data Label...

Page 3: ...uctions 18 Maintenance Preventative Maintenance 19 Winterizing Procedure 19 High Limit Hot Water Thermostat 19 Heating Coils 19 Gas Valve Regulator 20 Electrode Adjustment 20 Pilot Burner Adjustment 2...

Page 4: ...ts in good working condition They are listed in this general order Winterizing Procedure High Limit Hot Water Thermostat Heating Coils Gas Valve Regulator Electrode Adjustment Pilot Burner Adjustment...

Page 5: ...g parts please specify model and serial number Use only identical replacement parts This machine is to be used only by trained operators Important Safety Information NOTE This heater module NG 3000 is...

Page 6: ...machine with wet hands or while standing in water Always disconnect power before servicing WARNING Flammable liquids can create fumes which can ignite causing property damage or severe injury AVERTISS...

Page 7: ...ult in injury from a whipping wand AVERTISSEMENT Agripper la lance de nettoyage avec les deux mains avant de commencer Le non respect de cette consigne pourrait mener des blessures caus es par le mouv...

Page 8: ...ent 22 Never expose a spark or flame where there may be unburned gas present CAUTION This product incorporates parts that produce sparks and therefore when located in a garage it should be in a room o...

Page 9: ...High Pressure Nozzle not included Electric Cold Water Pressure Washer not included Vent according to local codes not included Burner Switch Spray Gun not included High Pressure Hose Not included Use...

Page 10: ...officials regarding any specific code or regu lations governing the installation The installation must conform to local codes The gas pressure coming out of the regulator and going to the burner ring...

Page 11: ...uit Joint compounds pipe dope should be used sparingly on male threads only and be approved for all gases Propane Gas The following pipe and stack sizes are just recommen dations Always consult a loca...

Page 12: ...rter Input BTU Per Hour Draft Hood Flue Pipe Size 250 000 320 000 8 inch 320 000 410 000 9 inch NOTE If the flue pipe exceeds 10 ft in length or contains more than two elbows use next size larger pipe...

Page 13: ...nd Testing Gas Piping The building structure should not be weakened by installing the gas piping The piping should not be supported by other piping but should be firmly supported with gas hooks straps...

Page 14: ...a soap solution With the main burner on coat pipe and tubing joints gaskets etc Bubbles indicate leaks 14 If the machine is installed in an enclosed room care should be taken to ensure that an adequa...

Page 15: ...Is there ample water supply Have all flammable liquids or gases been removed from installation location Is there adequate gas supply for the BTU rating of the burner Is incoming gas supply pressure to...

Page 16: ...from Pressure Washer Inlet Connector Control Knob Red Ignitor STEP 5 Depress control knob all the way and hold it in After five 5 seconds depress the red ignitor until you hear a loud click Repeat 3...

Page 17: ...If painted surfaces are peeling or chipping use extreme caution as pressure washer may remove the loose paint from the surface Keep the spray nozzle a safe distance from the surface you plan to clean...

Page 18: ...4 Turn water off Drain water from coil to prevent freezing STEP 2 Rinse detergent with fresh water if attached pressure washer is able to apply detergent STEP 3 After water has cooled turn the attache...

Page 19: ...o the discharge coupling fitting and by injecting compressed air all water will be blown out of the system The use of a draft diverter will prevent the wind chill factor from freezing the coil High Li...

Page 20: ...ly to prevent blockage Propane Gas Optional Conversion Kit General Safety Precautions Have a qualified gas service person assist in any gas burner installation or service Few maintenance people or mec...

Page 21: ...nning time desired Burner Features Operated Automatic Valve This machine is equipped with a thermopile self powered combination gas control This system is designed as a constant burning pilot Lighting...

Page 22: ...follows B Thermopile Output Reading Check B Reading Switch contacts OPEN Main burner OFF If the minimum 250 millivolt reading is not obtainable readjust pilot for maximum millivolt output If millivol...

Page 23: ...Restricted pilot line or clogged pilot orifice Clean pilot tubing and orifices PILOT LIT BUT MAIN BURNER WON T COME ON Faulty wiring Test wiring Low pilot flame Check inlet pressure pilot orifice pos...

Page 24: ...24 Notes Landa NG 3000 Operator s Manual 8 913 942 0 E...

Page 25: ...25 Parts Parts LANDA NG 3000 Landa NG 3000 Operator s Manual 8 913 942 0 E...

Page 26: ...913 942 0 E 35 41 37 25 36 33 34 14 28 27 26 42 47 50 62 63 30 49 32 48 31 29 30 68 16 3 4 5 10 9 7 6 2 8 38 13 40 37 21 60 52 15 19 71 20 53 37 25 36 44 50 22 17 18 72 11 12 39 53 37 69 43 51 66 67 2...

Page 27: ...18 9 802 678 0 1 IGNITOR PIEZO 19 8 719 968 0 1 HOLDER WAND ZINC PLATED 20 9 802 807 0 9 WASHER 3 8 SAE FLAT 21 9 802 779 0 8 NUT 3 8 ESNA 22 9 800 031 0 1 LABEL PILOT LIGHT WARNING 23 8 706 236 0 1...

Page 28: ...EL MANUFACTURER S CLEANING SOLUTION 56 9 800 021 0 1 LABEL HOT WATER OUTLET 57 9 803 563 0 1 CONNECTOR 1 4 TUBE X 1 8 MPT 58 8 706 910 0 1 BUSHING 1 4 X 1 8 PIPE 59 9 802 682 0 1 TAB GROUND 60 9 802 7...

Page 29: ...29 Landa NG 3000 Operator s Manual 8 913 942 0 E Notes...

Page 30: ...8 913 942 0 Printed in U S A...