![background image](http://html1.mh-extra.com/html/landa/ng-3000/ng-3000_operators-manual_4570729016.webp)
16
Operations
Operation Instruction
STEP 1:
Failure to read operation
and warning instructions may result
in personal injury or property
damage. Turn all switches off and
review installation and operating
instructions for attached pressure
washer before connecting the
water supply hose from the
pressure washer to the inlet
connector on the NG and turning
the water on. Check for water leaks
and tighten as needed.
STEP 2:
Connect the power cord
from the attached electric cold
water pressure washer to the
proper electrical outlet according to
the specifications and serial plate
information from the manufacturer.
STEP 3:
Review the installation
instructions and then turn on the
main gas supply.
Partially depress and turn control
knob to the “OFF” position.
STEP 4:
Wait five minutes to allow
gas which may have accumulated
in the main burner compartment to
escape then turn control knob to
“PILOT” position.
Landa NG 3000 Operator’s Manual 8.913-942.0 - E
Water Supply
Hose from
Pressure Washer
Inlet
Connector
Control
Knob
Red
Ignitor
STEP 5:
Depress control knob all the way and hold it in.
After five (5) seconds, depress the red ignitor until you
hear a loud click. Repeat 3 or 4 times if necessary until
pilot is lit. If pilot does not remain lit, repeat the
operation allowing a longer period of time before
releasing the control knob.
NOTE:
Burner may not
ignite on initial start up until air has been emitted from
the gas supply lines.
After the pilot lights, continue to hold the control knob
down for about one (1) minute before releasing.
NOTE:
Sufficient time must be allowed for a proper size
pilot flame to heat the thermocouple and hold the safety
magnet in a locked-up position. Also, time must be
allowed for air to escape from the lines during the first
operation.
Release control knob from pilot position and turn to full
or “ON” position.
STEP 6:
Start the attached pressure washer according
to the manufacturer’s instructions. Pull the trigger on
the spray gun allowing cold water to flow.
STEP 7:
For hot water, push the burner switch to the
“ON” position and pull the trigger on the spray gun, to
activate the gas control valve.
Burner
Switch
Summary of Contents for NG-3000
Page 2: ...2 Landa NG 3000 Operator s Manual 8 913 942 0 E Machine Data Label...
Page 24: ...24 Notes Landa NG 3000 Operator s Manual 8 913 942 0 E...
Page 25: ...25 Parts Parts LANDA NG 3000 Landa NG 3000 Operator s Manual 8 913 942 0 E...
Page 29: ...29 Landa NG 3000 Operator s Manual 8 913 942 0 E Notes...
Page 30: ...8 913 942 0 Printed in U S A...