background image

5

Safety

Introduction & Safety Information

Thank you for purchasing a Landa Heater Module.

This manual covers the operation and maintenance of 
the HS-3000 heater module. All information in this 
manual is based on the latest product information 
available at the time of printing.

Landa, Inc. reserves the right to make changes at any 
time without incurring any obligation.

Owner/User Responsibility:

The owner and/or user must have an understanding of 
the manufacturer’s operating instructions and warnings 
before using this Landa Heater Module. Warning infor-
mation should be emphasized and understood. If the 
operator is not fluent in English, the manufacturer’s 
instructions and warnings shall be read to and 
discussed with the operator in the operator’s native 
language by the purchaser/owner, making sure that the 
operator comprehends its contents.

Owner and/or user must study and maintain for future 
reference the manufacturers’ instructions.

SAVE THESE INSTRUCTIONS

This manual should be considered a permanent 
part of the machine and should remain with it if 
machine is resold.

When ordering parts, please specify model and
serial number. use only identical replacement 
parts.

This machine is to be used only by trained opera-
tors.

Important Safety Information

NOTE: This heater module HS-3000 is designed 
for connection to a pressure washer (not 
included). Read and follow WARNING and 
operating instructions of pressure washer 
connected to model HS-3000.

CAUTION: To reduce the risk of 
injury, read operating instructions 
carefully before using.

ATTENTION: Pour réduire le 
risque de blessures, lire attentive-
ment les instructions de 
fonctionnement avant l'utilisation.

1. Read the owner's manual thoroughly. Failure to 

follow instructions could cause malfunction of the 
machine and result in death, serious bodily injury 
and/or property damage. 

2. Know how to stop this product and bleed pressures 

quickly. Be thoroughly familiar with the controls.

3. Stay alert - watch what you are doing.

4. All installations must comply with local codes. 

Contact your electrician, plumber, utility company 
or the selling dealer for specific details.

To comply with the National Electric Code (NFPA 
70) and provide additional protection from risk of 
shock, this product is provided with a ground fault 
circuit interrupter (GFCI) built into the power cord 
plug (250V 30 amp or less, 1 PH). If replacement of 
the plug or cord is needed, use only identical 
replacement parts.

WARNING: Must be plugged into properly wired 
three hole grounded outlet that accommodates 
plug on power cord. Failure to comply could result 
in electrical shock.

AVERTISSEMENT: Doit être raccordé dans une 
sortie à trois trous mise à la masse et correctement 
câblée qui peut accueillir une fiche sur un cordon 
d'alimentation. Le non-respect de cette consigne 
pourrait causer un choc électrique.

DANGER: Improper connection of the equipment-
grounding conductor can result in a risk of electro-
cution. Check with a qualified electrician or service 
personnel if you are in doubt as to whether the 
outlet is properly grounded. Do not modify the plug 
provided with the product - if it will not fit the outlet, 
have a proper outlet installed by a qualified electri-
cian. 

DANGER: Une mauvaise connexion du conducteur 
de terre de l'équipement peut entraîner un risque 
d'électrocution. Vérifier auprès d'un électricien 
qualifié ou du personnel d'entretien si vous avez 
des doutes quant à savoir si lasortie est correcte-
ment mise à la masse. NE PAS modifier la fiche 
fournie avec le produit - si elle n'entre pas dans la 
sortie, faire installer une sortie appropriée par un 
électricien qualifié.

Landa HS  Operator’s Manual  8.913-943.0 - P

WARNING

    READ SAFETY 

 INSTRUCTIONS PRIOR

TO INSTALLING OR 

SERVICING MACHINE

OPERATIONS

SAFET

Y

MAINTENANCE

Summary of Contents for 1.103-900.0

Page 1: ...8 913 943 0 P 12 13 19 HS Series Hot Water Generator Operator s Manual Heater Module 12 MODELS HS 3000 1 103 900 0...

Page 2: ...2 Landa HS Operator s Manual 8 913 943 0 P Machine Data Label...

Page 3: ...ing 13 Shutting Down And Clean up 13 Storage 13 After Extended Storage 13 Maintenance Preventative Maintenance 14 Winterizing Procedure 14 High Limit Thermostat 14 Cleaning of Coils 14 Removal of Soot...

Page 4: ...e main tenance to keep the machine and its components in good working condition They are listed in this general order Winterizing Procedure High Limit Thermostat Cleaning of Coils Rupture Disk Fuel Ig...

Page 5: ...e and result in death serious bodily injury and or property damage 2 Know how to stop this product and bleed pressures quickly Be thoroughly familiar with the controls 3 Stay alert watch what you are...

Page 6: ...ing WARNING Spray gun kicks back hold with both hands AVERTISSEMENT Le pistolet pulv risateur peut pr senter un risque de retour le tenir avec les deux mains 8 Grip cleaning wand securely with both ha...

Page 7: ...der scaffolding or any other relatively unstable location The cleaning area should have adequate slopes and drainage to reduce the possibility of a fall due to slippery surfaces AVERTISSEMENT Faire pr...

Page 8: ...in this machine is hot The wand and spray gun must be insulated Hose spray gun wand and attached pressure washer not included on the HS 3000 Spray Gun HS Burner Switch 15 Amp GFCI Collar Insulated Ha...

Page 9: ...d tente du pistolet pulv risateur STEP 2 Connect high pressure hose from the attached pressure washer not included to the hot water discharge nipple by sliding quick coupler collar back Insert quick c...

Page 10: ...ent supply of oxygen available for the amount of fuel being burned Electrical This machine when installed must be electrically grounded in accordance to local codes Check for proper power supply using...

Page 11: ...cleaning STEP 3 For hot water washing turn the HS burner switch to the ON position The burner will light auto matically Landa HS Operator s Manual 8 913 943 0 P Burner Switch Variable Pressure Contro...

Page 12: ...Cleaning Tips Pre rinse cleaning surface with fresh water Place detergent suction tube directly into cleaning solution and apply to surface at low pressure for best results limit your work area to sec...

Page 13: ...low 32 F 0 C The heating coil in this machine is susceptible to permanent damage if frozen FREEZE DAMAGE IS NOT COVERED BY WARRANTY ATTENTION Toujours entreposer la laveuse pression dans un endroit o...

Page 14: ...her should be kept clean and free of combustible materials gasoline and other flammable vapors and liquids The flow of combustion and ventilating air to the burner must not be blocked or obstructed in...

Page 15: ...hours of operation Use No 1 or No 2 Heating Oil ASTM D306 only NEVER use gasoline in your burner tank Gasoline is more combustible than fuel oil and could result in a serious explosion NEVER use cran...

Page 16: ...te temperatures of between 40 F and 90 F Colder temperatures will make for a thicker flow and less fine a fuel spray while hotter temperatures will make for a thinner flow a more fine spray with the s...

Page 17: ...to the thermostat 3 Remove rupture disk and associated fittings 4 Remove the 3 3 8 bolts from each side of coil and tank assembly these bolts are used to fasten handles to chassis 5 Remove burner asse...

Page 18: ...turn machine on open spray gun and check for magnetic pull Clogged burner nozzle Replace Water not turned on Turn on water to activate burner flow switch Flow switch malfunction Remove test for conti...

Page 19: ...coils using Landa s coil cleaner Improper burner nozzle See exploded view parts list WATER TEMPERATURE TOO HOT Incoming water to machine warm or hot Lower incoming water temperature Fuel Pump pressur...

Page 20: ...ance of your equipment Contact your Landa dealer for maintenance Regular preventative maintenance will add many hours to the life of your pressure washer Perform maintenance more often under severe co...

Page 21: ...e pump oil after first 50 hours and every year or 500 hours thereafter Use SAE 10W 40 non foaming oil DateOil Changed Month Day Year Estimated Operating Hours Since Last Oil Change DateOil Changed Mon...

Page 22: ...22 Notes Landa HS Operator s Manual 8 913 943 0 P...

Page 23: ...8 913 943 0 Printed in U S A...

Reviews: