background image

17

Maintenance

To adjust:

 start machine and turn burner ON. Loosen 

two locking screws found on the air band (refer to illus-
tration) and close openings until black smoke appears 
from burner exhaust vent. Note air band position. Next, 
slowly open the air band until white smoke just starts to 
appear. Turn air band halfway back to the black smoke 
position previously noted. Tighten locking screws.

Coil Removal HS-3000

Removal of the coil, because of freeze breakage, 
thermal expansion or to clean soot from it, can be done 
quickly and easily.

1. Disconnect hose from inlet side of the coil.

2. Disconnect electrical connection to the 

thermostat.

3. Remove rupture disk and associated fittings.

4. Remove the 3-3/8" bolts from each side of coil and 

tank assembly (these bolts are used to fasten 
handles to chassis).

5. Remove burner assembly from combustion 

chamber.

6. Disconnect 1/2" pipe nipples and tee fittings from 

inlet and discharge side of coil.

7. Remove top tank wrap exposing insulation and 

coil. Bend back insulation tabs in exhaust stack. 
Then fold back insulation.

8. Remove bolts from underneath that hold down coil 

to bottom wrap.

9. Remove coil.

10. Replace or repair any insulation found to be torn or 

broken.

11. Reinstall new or cleaned coil reversing Steps 9 

through 1.

NOTE:

 Before step 6, lift coil and tank assembly onto 

some type of exposed support for ease of removing 
inlet and discharge fittings.

Landa HS  Operator’s Manual  8.913-943.0 - P

Summary of Contents for 1.103-900.0

Page 1: ...8 913 943 0 P 12 13 19 HS Series Hot Water Generator Operator s Manual Heater Module 12 MODELS HS 3000 1 103 900 0...

Page 2: ...2 Landa HS Operator s Manual 8 913 943 0 P Machine Data Label...

Page 3: ...ing 13 Shutting Down And Clean up 13 Storage 13 After Extended Storage 13 Maintenance Preventative Maintenance 14 Winterizing Procedure 14 High Limit Thermostat 14 Cleaning of Coils 14 Removal of Soot...

Page 4: ...e main tenance to keep the machine and its components in good working condition They are listed in this general order Winterizing Procedure High Limit Thermostat Cleaning of Coils Rupture Disk Fuel Ig...

Page 5: ...e and result in death serious bodily injury and or property damage 2 Know how to stop this product and bleed pressures quickly Be thoroughly familiar with the controls 3 Stay alert watch what you are...

Page 6: ...ing WARNING Spray gun kicks back hold with both hands AVERTISSEMENT Le pistolet pulv risateur peut pr senter un risque de retour le tenir avec les deux mains 8 Grip cleaning wand securely with both ha...

Page 7: ...der scaffolding or any other relatively unstable location The cleaning area should have adequate slopes and drainage to reduce the possibility of a fall due to slippery surfaces AVERTISSEMENT Faire pr...

Page 8: ...in this machine is hot The wand and spray gun must be insulated Hose spray gun wand and attached pressure washer not included on the HS 3000 Spray Gun HS Burner Switch 15 Amp GFCI Collar Insulated Ha...

Page 9: ...d tente du pistolet pulv risateur STEP 2 Connect high pressure hose from the attached pressure washer not included to the hot water discharge nipple by sliding quick coupler collar back Insert quick c...

Page 10: ...ent supply of oxygen available for the amount of fuel being burned Electrical This machine when installed must be electrically grounded in accordance to local codes Check for proper power supply using...

Page 11: ...cleaning STEP 3 For hot water washing turn the HS burner switch to the ON position The burner will light auto matically Landa HS Operator s Manual 8 913 943 0 P Burner Switch Variable Pressure Contro...

Page 12: ...Cleaning Tips Pre rinse cleaning surface with fresh water Place detergent suction tube directly into cleaning solution and apply to surface at low pressure for best results limit your work area to sec...

Page 13: ...low 32 F 0 C The heating coil in this machine is susceptible to permanent damage if frozen FREEZE DAMAGE IS NOT COVERED BY WARRANTY ATTENTION Toujours entreposer la laveuse pression dans un endroit o...

Page 14: ...her should be kept clean and free of combustible materials gasoline and other flammable vapors and liquids The flow of combustion and ventilating air to the burner must not be blocked or obstructed in...

Page 15: ...hours of operation Use No 1 or No 2 Heating Oil ASTM D306 only NEVER use gasoline in your burner tank Gasoline is more combustible than fuel oil and could result in a serious explosion NEVER use cran...

Page 16: ...te temperatures of between 40 F and 90 F Colder temperatures will make for a thicker flow and less fine a fuel spray while hotter temperatures will make for a thinner flow a more fine spray with the s...

Page 17: ...to the thermostat 3 Remove rupture disk and associated fittings 4 Remove the 3 3 8 bolts from each side of coil and tank assembly these bolts are used to fasten handles to chassis 5 Remove burner asse...

Page 18: ...turn machine on open spray gun and check for magnetic pull Clogged burner nozzle Replace Water not turned on Turn on water to activate burner flow switch Flow switch malfunction Remove test for conti...

Page 19: ...coils using Landa s coil cleaner Improper burner nozzle See exploded view parts list WATER TEMPERATURE TOO HOT Incoming water to machine warm or hot Lower incoming water temperature Fuel Pump pressur...

Page 20: ...ance of your equipment Contact your Landa dealer for maintenance Regular preventative maintenance will add many hours to the life of your pressure washer Perform maintenance more often under severe co...

Page 21: ...e pump oil after first 50 hours and every year or 500 hours thereafter Use SAE 10W 40 non foaming oil DateOil Changed Month Day Year Estimated Operating Hours Since Last Oil Change DateOil Changed Mon...

Page 22: ...22 Notes Landa HS Operator s Manual 8 913 943 0 P...

Page 23: ...8 913 943 0 Printed in U S A...

Reviews: