Page 3
User Guide
198.240
1.2
Specifications - LSP Series
Specification
LSP5FL
LSP50
LSP52
LSP61
Operating Wavelength:
5
µ
m
3 to 5
µ
m
Temperature Range:
150 to 750°C/
150 to 750°C/
500 to 1100°C/
50 to 400°C/
302 to 1382°F
302 to 1382°F
932 to 2012°F
122 to 752°F
System Accuracy:
+/-2°C
+/-3°C
+/-2°C
Repeatability:
1°C
Temperature Resolution:
Below 15% of range
<1.5°C
<2.5°C
<2.0°C
Above 15% of range
<1.0°C
<2.5°C
<1.0°C
Scan Angle:
80°
Scan Rate:
Factory set
20Hz
50Hz
User adjustable
10 to 100Hz in 10Hz steps
Target Width:
Target distance
<1200mm/47.2in
12mm / 0.5in
Target distance
1200 to 3000mm/
47.2 to 118.1in
FoV 100:1
Speed Of Response:
Tau on rising edge
(linear output)
<7
µ
s
Ambient Temperature Range:
In specification
5 to 60°C / 41 to 140°F
Operating
5 to 70°C / 41 to 158°F
Ambient Stability:
∆
T(Indicated)/
∆
T(Ambient)
<1.0°/10°
<2.0°/10°
<1.0°/10°
Alignment:
No alignment
CLASS 2 Laser: Integrated laser indicating scan
aid
plane and extents. Laser scan rate: 1Hz nominal
Internal Temperature Sensor:
-10 to 90°C / 14 to 194°F
Emissivity Range:
0.20 to 1.00
Sealing:
IP65
EMC:
EN 61320:1999 Class A (emissions & immunity), IEC 1010 (safety)
Vibration:
2g 10 to 30Hz, 3g 30 to 300Hz; any axis