7. Plug in power cord to power supply then route power supply
cord to the designated grounded electrical outlet.
DO NOT PLUG UNIT INTO GROUNDED ELECTRICAL
OUTLET AT THIS TIME.
Make sure that all water lines
are tight and unit is dry before making any electrical
connections
!
WARNING
4. Route appropriate tubing for the carbonated/plain water
inlets then connect tubing to inlet. Repeat for all water
connections including the return inlet.
A
B
A. Tower
B. Drip Tray
C. Magnet Connection
in Tower
C
A
D
E
C
B
A. Drip Tray
B. Counter
C. Upper Drain Fitting
D. Lower Drain Fitting
E. Washer
6. If a drain line is to be utilized, place gasket at the bottom of
the drain then attach drain fitting to drip tray.
If a drain line is utilized, then connect ADA wire
harness in drip tray to the wire harness behind splash
plate before attaching drip tray.
!
ATTENTION
Dispenser Setup
1. Remove the cup rest from drip tray.
2. Remove the nozzle by twisting clockwise and pulling down.
8. Connect power cord to grounded electrical outlet.
Unit is designed to be supported by a remote chiller
system or remote ice cooled system. Please see the
manufacturer’s specifications and instructions for
installation. The following are the instructions for
plumbing the remote chiller system to the tower.
NOTE
A. Nozzle
A
3. Remove the splash plate.
4. Turn on the water supply.
5. Verify all Bag-in-Box contain syrup and check for leaks.
6. Open the pressure relief valve located on the remote chiller
system by flipping up on the valve cap lever. Hold open until
water flows from the relief valve then close (flip down) relief
valve. (If applicable)
7. Using a screwdriver, remove the top two screws of the top
plate then slide plate back slightly and lift from the front edge
to remove.
A. Top Plate Screw
B. Touchscreen
A
A
B
8. Route appropriate tubing from the syrup pump location to
the syrup inlets at the remote chiller. Repeat for all syrup
connections.
9. Route appropriate tubing from the water source to the water
inlet at the remote chiller and only connect tubing to the
water source.
10. Turn on the water and flush the water line thoroughly.
11. Turn off the water and connect water line to the plain water
inlet at the remote chiller.
A
B
C
A. Oetiker Pliers
B. Fitting
C. Tubing
D. Syrup/Water
Inlet
D
5. Slide drip tray into opening in tower until magnets engage
and lock drip tray in place. Connect ADA wire harness from
drip tray to ADA wire harness in tower.