INSTALLATION
Unpack the Dispenser
1. Cut package banding straps and remove.
2. Open the box and remove the accessory kit and loose parts.
3. Carefully lift the unit out of the box and place on a flat
surface taking care to not scratch the plastic covers.
Inspect unit for concealed damage. If evident, notify
delivering carrier and file a claim against the same.
NOTE
Selecting/Preparing Counter Location
Dispenser Installation
1. Using proper lifting techniques, lift the tower over the counter
top, then route end of power cord through the designated
opening in the counter.
2. Slide the tower into the cutout in the counter and use the
screws and mounting brackets provided to secure the tower
to the counter.
Inspect the counter location where the unit is to be
installed. Verify the selected counter is strong enough
to safely support the weight of the installed unit, after
the cutout for the unit is made. The ideal counter for
installation should measure at least 25 mm (1 inch)
thick.
!
ATTENTION
1. Select a location that is in close proximity to a properly
grounded electrical outlet, within five (5) feet (1.5 m) of
a drain, and a water supply that meets the requirements
shown in the Specifications section found on page 2.
To assure that beverage service is accessible to all
customers, Lancer recommends that counter height
and equipment selection be planned carefully. The
2010 ADA Standards for Accessible Design states that
the maximum reach height from the floor should be no
more than 48 in (1.2 m) if touch point is less than 10 in
(254 mm) from the front of the counter, or a maximum
of 46 in (1.17 m) if the touch point is more than 10 in
(254 mm) and less than 27 in (685 mm) from the front of
the counter. For more information about the customer’s
legal requirements for the accessibility of installed
equipment, refer to 2010 ADA Standards for Accessible
Design - http://www.ada.gov.
NOTE
When attaching the tower to the counter, make sure the
screws do not extend more than 0.75 in (19 mm) from
the top of the counter. These could damage the valves
when installing the dispenser.
!
ATTENTION
Min: 0.75 in
Max: 2.75 in
Min: 2.0 in
Max: 1.5 in
Max: 48.0 in
A. Drain Tube
B. Inlet Tubes
A
B
3. Select a location for the remote chiller system or carbonator
(if necessary), syrup pumps, CO
2
tank, syrup containers,
and water filter (recommended).
4. Using Counter Cutout Template provided (and on the back
of this manual) cut out required opening for the tower
installation in the designated location.
NSF listed units must be sealed to the counter.
NOTE
A
B
C
A. Tower
B. Syrup/Water Inlets
C. Mounting Brackets
(Underneath Counter)
D. Connection Screws
(Underneath Counter)
D
C
3. Route appropriate tubing from the syrup pump location to the
syrup inlets on the tower. Connect tubing to inlets using the
oetiker pliers and fittings. Repeat for all syrup connections.
The dispenser should only be installed in a location
where it can be overseen by trained personnel
NOTE
2. Select a location that utilizes the clearances/space required
for installation.