The dispenser is for indoor use only

• 

This appliance is intended to be used in commercial 

applications such as restaurants or similar.

• 

This appliance should not be used by children or 

infirm persons without supervision. 

• 

This appliance is not intended for use by persons 

(including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and       

knowledge, unless they have been given supervision 

or instruction concerning use of the appliance by a 

person responsible for their safety. 

• 

This appliance can be used by children aged from 8 

years and above and persons with reduced physical, 

sensory or mental capabilities or lack of experience 

and knowledge if they have been given supervision or 

instruction concerning use of the appliance in a safe 

way and understand the hazards involved.

• 

Cleaning and user maintenance shall not be          

performed by children without supervision.

• 

This unit is not a toy and children should be advised 

not to play with the appliance.

• 

The min/max ambient operating temperature for the 

dispenser is 40°F to 105°F (4°C to 41°C). 

• 

Do not operate unit below minimum ambient operation 

conditions. 

• 

Should freezing occur, cease operation of the unit and 

contact authorized service technician.

• 

The maximum tilt for safe operation is 5°. 

• 

This appliance must be installed and serviced by a 

professional.

Intended Use

• 

Follow all local electrical codes when making         

connections.

• 

Check the dispenser name plate label, located behind 

the splash plate for correct electrical requirements 

of the unit. 

DO NOT

 plug into a wall electrical outlet 

unless the current shown on the serial number plate 

agrees with local current available.

• 

Each dispenser must have a separate electrical 

circuit. 

•  DO NOT

 use extension cords with this unit.  

•  DO NOT

 ‘gang’  together with other electrical devices 

on the same outlet.

•  WARNING: 

Always disconnect electrical power to the 

unit to prevent personal injury before attempting any 

internal maintenance. 

• 

The resettable breaker switch should not be used as 

a substitute for unplugging the dispenser from the 

power source to service the unit. 

• 

Only qualified personnel should service internal    

components of electrical control housing. 

•  WARNING: 

Make sure that all water lines are tight and 

units are dry before making any electrical connections 

• 

If this dispenser is installed in an area that is          

susceptible to ±10% variation of the nominal line    

voltage, consider installing a surge protector or similar 

protection device.

Power

IMPORTANT SAFETY INSTRUCTIONS

•  WARNING:

 Carbon Dioxide (CO2) is a colorless,      

noncombustible gas with a light pungent odor. High 

percentages of CO

2

 may displace oxygen in the 

blood. 

•  WARNING: 

Prolonged exposure to CO

2

  can  be  harmful.           

Personnel exposed to high concentrations of CO

2

 gas 

will experience tremors which are followed by a loss 

of consciousness and suffocation. 

•  WARNING: 

If a CO

2

 gas leak is suspected, immediately 

ventilate the contaminated area before attempting to 

repair the leak. 

•  WARNING: 

Strict attention must be observed in the 

prevention of CO

2

 gas leaks in the entire CO

2

 and soft 

drink system.

Carbon Dioxide (CO

2

)

• 

Provide an adequate, potable water supply. Water 

pipe connections and fixtures directly connected to 

a potable water supply must be sized, installed, and 

maintained according to federal, state, and local 

codes.

• 

The water supply line must be at least a 3/8 inches 

(9.525 mm) pipe with a minimym of 25 PSI (0.172 

MPA) line pressure

, but not exceeding a maximum of 

50 PSI (0.345 MPA).  Water pressure exceeding 50 

PSI (0.345 MPA) must be reduced to 50 PSI (0.345 

MPA).

• 

Use a filter in the water line to avoid equipment 

damage and beverage off-taste. Check the water filter 

periodically, as required by local conditions.

•  CAUTION: 

The water supply must be protected by 

means of an air gap, a backflow prevention device  

(located upstream of the CO

2

 injection system) 

or another approved method to comply with NSF           

standards. 

A leaking inlet water check valve will         

allow carbonated water to flow back through the pump 

when it is shut off and contaminate the water supply.

•  CAUTION: 

Ensure the backflow prevention device   

complies with ASSE and local standards. It is the 

responsibility of the installer to ensure compliance.

Water Notice

Summary of Contents for Sensation

Page 1: ...emark of Lancer 2016 by Lancer all rights reserved Lancer Corporation 6655 Lancer Blvd San Antonio Texas 78219 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp c...

Page 2: ...ONS AND PART LISTINGS 22 25 Main Unit Assembly 22 23 Wiring Diagram 115 Volt 24 Plumbing Diagram 25 Counter Cutout 25 READ ALL SAFETY INSTRUCTIONS BEFORE USING THIS UNIT This manual contains important...

Page 3: ...d as a substitute for unplugging the dispenser from the power source to service the unit Only qualified personnel should service internal components of electrical control housing WARNING Make sure tha...

Page 4: ...OXIDE CO2 SUPPLY Min Pressure 70 PSIG 0 483 MPA Max Pressure 80 PSIG 0 552 MPA FITTINGS Carbonator Inlet 3 8 inch barb Plain Water Inlet 3 8 inch barb Brand Syrup Inlets 3 8 inch barb Units are equipp...

Page 5: ...ve enough space to install the dispenser Is countertop level Can the countertop support the weight of the dispenser Include the weight of an ice machine plus weight of ice if necessary Is dispenser lo...

Page 6: ...each under the shroud to ensure the drain spider is secure in the coldplate cutout If the spider is not in place proceed with the following steps NOTE Inspect unit for concealed damage If evident noti...

Page 7: ...MINIMUM of 6 152 mm AIR IN AIR IN e c n a r a e l c m m 2 5 1 6 e c n a r a e l c m m 2 5 1 6 22 559 mm M U M I N I M of 6 152 mm 34 864 mm 30 1 2 775 mm clearance above ice maker MINIMUM of 6 152 mm...

Page 8: ...hich can cause damage to your dispenser ATTENTION 1 Install the icemaker per manufacturer specifications Points of consideration include drainage ventilation and drop zones 2 An adapter plate is requi...

Page 9: ...ouring hot water into drain may cause the Drain Tube to collapse Allow only luke warm or cold water to enter Drain Tube Pouring coffee tea and similar substances into drain may cause the Drain Tube to...

Page 10: ...ng at syrup pumps A B C A Syrup Pump Outlet B Syrup Pump C Fitting 4 Connect tubing from dispenser syrup inlet to the syrup pump outlet fitting Repeat for each syrup line pump Re peat Steps 1 5 for al...

Page 11: ...to source and connect tubing 4 Using a wrench loosen lock nut on the regulator adjustment screw of the high pressure CO2 regulator connected to the source then using a screwdriver back out lock nut s...

Page 12: ...begins to turn 7 Activate each valve to ensure a good flow of water is achieved 8 Ensure pump deck is turned OFF before turning on CO2 The pump deck has a 3 minute timeout feature If the timeout occu...

Page 13: ...ing down 5 Install Lancer yellow syrup seperator PN 54 0031 in place of nozzle 6 Re open syrup shut off at mounting block 7 Activate valve to purge syrup until steady flow is achieved 8 Using a Lancer...

Page 14: ...e detergent e g Sodium Laureth Sulfate dish soap with clean potable water at a temperature of 90 F to 110 F 32 C to 43 C The mixture ratio is one ounce of cleaner to two gallons of water Prepare a min...

Page 15: ...surfaces of the dispenser 13 Wearing sanitary gloves reassemble all removable parts Ensure agitator clip is locked 14 Fill Unit with ice and replace Top Cover 15 Reconnect Dispenser to power source 1...

Page 16: ...NOT rinse with water after sanitizing 7 Reconnect diffuser and nozzle 8 Connect power 9 Taste the drink to verify that there is no off taste If off taste is found flush syrup system again 5 Remove th...

Page 17: ...efective 1 Plug in wiring harness 2 Replace PC board 3 Replace motor Push chute motor runs but ice door does not open 1 Solenoid not connected to PC board 2 Solenoid defective 3 PC board defective 1 C...

Page 18: ...e Erratic ratio 1 Incoming water and or syrup supply not at min flowing pressure 2 Foreign debris in water and or syrup flow control 3 CO2 regulator malfunction 1 Check pressure and adjust 2 Remove fl...

Page 19: ...gas dispensed with syrup 1 Improper water flow to dispenser 2 Carbonator pump motor has timed out display message on the LCD screen 3 Liquid level probe not connected prop erly to PCB 4 Defective PCB...

Page 20: ...to 70 80 PSI 0 482 0 552 MPA 2 Replace syrup supply 3 Fasten connector tightly 4 Straighten or replace lines BIB pump operating but no flow 1 Leak in syrup inlet or outlet line 2 Defective BIB pump 1...

Page 21: ...light is off check to see if the internal circuit breaker on the transformer has tripped If it has tripped it can be reset by depressing the switch on the top of the transformer D7 This light flashes...

Page 22: ...et the agitation time should be less than the dispense time If using an icemaker the agitation time can be decreased 7 seconds 5 seconds 7 seconds 9 seconds 11 seconds To prevent possible harm to the...

Page 23: ...23 INTENTIONALLY LEFT BLANK...

Page 24: ...24 Main Unit Assembly ILLUSTRATIONS AND PART LISTINGS 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22...