Automatic Agitation and Low Ice Alarm Control
Each Series 4800 ice beverage dispenser is equipped with automatic agitation for the ice bin. Referring to the tables on the
wiring diagram included in this manual (also affixed to the electrical box cover), the automatic agitation timing can be changed as
follows. A set of DIP switches is provided to control the timing and low ice control. Refer to graph below.
DIP #3 & #4 – AUTOMATIC AGITATION FREQUENCY
The default ON time is preset to 3 seconds. Automatic agitation should not be used with extruded ice types. Only
use this feature when dispensing cubed ice.
DIP #5 through #8 – DISPENSE TIME/AGITATION SYNC
Switch
Function
Default Setting
Avail Time Settings
#7 and #8
Set the amount of total dispense time before
agitation occurs
12 seconds
6 seconds
9 seconds
12 seconds
15 seconds
#5 and #6
Set the agitation time (should be less than
the dispense time). If using an icemaker, the
agitation time can be decreased
7 seconds
5 seconds
7 seconds
9 seconds
11 seconds
To prevent possible harm to the environment from improper disposal, recycle the unit
by locating an authorized recycler or contact the retailer where the product was purchased.
Comply with local regulations regarding disposal of the refrigerant and insulation.
Dispenser Disposal
55
4
7
DIP SWITCH LEGEND
4
2
ON
ON
ON
7
SW2 SWITCH 1: MUST BE ON FOR
CORRECT OPERATION
2
1
6
SW1 SWITCH 2: "LOW ICE"
ALARM ENABLED
58
3
6
8
7
3
8
ON
SW2
SW1
6
5
LANCER PN: 06-3289
3
SW1
7
1
6
4
2
SW1 SWITCH 1: "LOW ICE" LED
INDICATOR ENABLED
1
4
2
3
1
2
8
1
SWITCH #
REFILL START
AFTER
7
8
OFF
OFF
6 SEC DISPENSED
OFF
ON
9 SEC DISPENSED
ON
OFF
12 SEC DISPENSED
ON
ON
15 SEC DISPENSED
SWITCH #
REFILL ON
TIME
5
6
OFF
OFF
11 SECONDS
OFF
ON
9 SECONDS
ON
OFF
7 SECONDS
ON
ON
5 SECONDS
SWITCH #
AUTO AGITATE
OFF TIME
3
4
OFF
OFF
NO AUTO AGITATION
OFF
ON
20 MINUTES
ON
OFF
40 MINUTES
ON
ON
60 MINUTES