background image

6

Installing CO

2

 Supply

1.  Connect high pressure CO

2

 regulator assembly to CO

2

      

cylinder or bulk system.

Thread regulator nut on to tank, then   

 

tighten nut with wrench

A. CO

2

 Regulator

B. Outlet

C. Wrench

D. CO

Supply

A

B

C

D

 

Before installing regulator, assure that a seal (washer 

or o-ring) is present in regulator attachment nut.

ATTENTION

2.  Connect a 1/4” nut, stem and seal to CO

2

 regulator outlet.

3.  Route appropriate tubing from the low pressure CO

2

         

regulator manifold location to the 1/4” nut, stem on the high 

pressure CO

2

 regulator attached to source and connect 

tubing.

 

A dedicated CO

2

 regulator is required to supply the CO

2

 

inlet at the unit as well as to all syrup pumps. 

ATTENTION

 

DO NOT PLUG UNIT INTO GROUNDED ELECTRICAL 

OUTLET AT THIS TIME. 

Make sure that all water lines 

are tight and unit is dry before making any electrical 

connections

WARNING

 

Drain line must be insulated with a closed cell 

 

insulation. Insulation must cover the entire length of 

the drain hose, including fittings. The drain should be 

installed in such a manner that water does not collect 

 

in sags or other low points, as condensation will form.

CAUTION

Pouring hot water down the drain may cause the Drain 

Tube to collapse. Allow only luke warm or cold water 

to enter the Drain Tube.

 

Pouring coffee, tea, or other 

similar substances down the drain may cause the 

Drain Tube to become clogged.

ATTENTION

A

A. Drain Fitting

B. Drain Line

C. Drip Tray

B

C

16.  Route drain hose from designated open type drain to both 

fittings on Drip Tray and connect hose to fittings. 

15.  Route the power supply cord to a grounded electrical outlet 

of the proper voltage and amperage rating.

17.  Reattach Drip Tray and Cup Rest to unit.

A

A. Cold Plate Drain

B. Drip Tray

C. CO

2

 Line

B

C

 

When installing the drip tray, make sure both of the 

 

cold plate drain hoses are lined up to the openings in 

 

the drip tray. Make sure the end of the hose rests at 

 

least a half of an inch over the edge of the opening to 

ensure proper drainage of the cold plate.

NOTE

A

B

A. Pressure Relief Valve

B. CO

2

 Inlet

13.  Route appropriate tubing from the syrup pump location to the 

syrup inlets and connect tubing to all syrup inlets. 

14.  Route appropriate tubing from the CO

2

 source location to the 

CO

2

 inlet on the unit and connect tubing to inlet.

4.  Connect tubing routed from the CO

2

 inlet at the unit to one of 

the low pressure CO

2

 regulator manifold outlets.

Summary of Contents for Sensation 44

Page 1: ...cess or for your convenience scan this QR code with a mobile device app required for immediate access to other Technical Documents and alternative translations if available pertaining to this unit Con...

Page 2: ...acity 312 lbs 142 kg CARBON DIOXIDE CO2 SUPPLY Min Pressure 70 psi 0 483 MPa Max Pressure 80 psi 0 552 MPa FITTINGS Carbonator Inlet 3 8 inch barb Plain Water Inlet 3 8 inch barb Brand Syrup Inlets 3...

Page 3: ...weight of the dispenser ice and possibly an icemaker being installed after counter cut out is made Total weight with icemaker for this unit could exceed 800 pounds 363 6kg The dispenser should only b...

Page 4: ...r use a bin thermostat to control the ice level see below This will prevent damage to the dispensing mechanism The bracket for mounting a thermostat is located in the ice bin During the automatic agit...

Page 5: ...ubing from the water source to the plain water inlet at the front of the unit and connect tubing to inlet using the oetiker pliers and fittings see Plumbing Diagrams on the front of the unit or on pag...

Page 6: ...nts as condensation will form CAUTION Pouring hot water down the drain may cause the Drain Tube to collapse Allow only luke warm or cold water to enter the Drain Tube Pouring coffee tea or other simil...

Page 7: ...just both of the low pressure regulators on the regulator manifold to 75 psi 0 517 MPa then tighten locknut with wrench 11 Activate each valve until gas out 12 Plug in the remote carbonator pump deck...

Page 8: ...quired to remove the merchandiser to gain access to valves NOTE 8 Using a Lancer ratio cup activate the valve and capture a sample Verify that the syrup level is even with the water level Use a screwd...

Page 9: ...mum of five gallons of cleaning solution Do not use abrasive cleaners or solvents because they can cause permanent damage to the unit Ensure rinsing is thorough using clean potable water at a temperat...

Page 10: ...on page 9 thoroughly wipe down the flavor injector nozzle and bracket then let air dry DO NOT rinse with water after sanitizing 6 Repeat Steps 2 5 for second flavor injector nozzle 7 Connect power 8...

Page 11: ...om Ice Chute link by pushing pin through shaft until link is free Pin shown in out position A B C A Agitator Clip Pin B Hub C Agitator Bar 22 Remove the Agitator bar and Hub from the Ice Bin 23 Remove...

Page 12: ...warm water and flush out syrup remaining in the lines 4 Prepare Cleaning Solution described on previous page 9 5 Place syrup lines with BIB connectors into cleaning solution 6 Activate each valve unt...

Page 13: ...13 PLUMBING DIAGRAM Sensation 44 Unit Plumbing Diagram Sensation 44 Flavor Shot Box Plumbing Diagram...

Page 14: ...14 WIRING DIAGRAMS Wiring Diagram 115 Volt...

Page 15: ...15 Wiring Diagram 220 240 Volt...

Page 16: ...6 7 6 2 2 3 8 3 4 7 4 5 SW1 SWITCH 1 NOT USED FOR MODEL 4900 ON 5 4 SWITCH AGITATOR ON TIME 5 6 OFF OFF 11 SECONDS OFF ON 9 SECONDS ON OFF 7 SECONDS ON ON 5 SECONDS SWITCH AUGER RUN TIME 7 8 OFF OFF 6...

Reviews: