background image

4

Merchandiser Installation/Removal

1.  To remove the merchandiser, first detach the left and right 

side of the merchandiser from the connection tabs by pulling 

away from the unit.

 

If installing a Scotsman

® 

icemaker, Lancer recommends 

setting the auto agitation time to every 60 minutes. To 

adjust the agitation time, set the dip switches located in 

the control box behind the merchandiser. See the DIP 

Switch Legend diagram on page 12 of this manual for 

reference.

NOTE

A

B

A. Detach from  

    Connection Tab

B. Merchandiser

A

B

A. Position Over  

    Valve Plates

B. Merchandiser

A

B

C

A. Rotate from Bottom

B. Merchandiser

C. Connection Tab

B

A

B

A. Push in Tab

B. Side Bracket

5.  Ensure the icemaker is installed properly to allow for removal 

of the Merchandiser.

6.  Ensure manual fill is accessible.
7.  Clean and maintain icemaker per manufacturer’s                

instructions.

5.  Position the lower edge of the merchandiser over each of the 

valve plates. 

3.  Lift the merchandiser straight up to detach from the top of 

the ice bin and remove from the unit.

4.  To install the merchandiser, firmly push the connection tabs 

toward the center of the unit in order to create a clear path 

for the install.

Installing an Icemaker (if necessary)

When installing an icemaker on the dispenser, use a 

bin thermostat to control the ice level (see below). This 

will prevent damage to the dispensing mechanism. The 

bracket for mounting a thermostat is located in the ice 

bin. During the automatic agitation cycle and while    

dispensing ice, ensure there is adequate space be-

tween the top of the ice level and the bottom of the 

icemaker so the ice can move without obstruction. 

Contact your icemaker manufacturer for information  

on a suitable bin thermostat.

ATTENTION

1.  Install the icemaker per manufacturer specifications. Points 

of consideration include drainage, ventilation, and drop 

zones.

2.  An adapter plate is required when installing an icemaker. 

Contact your Sales Representative or Lancer Customer 

Service for more information.

3.  A bin thermostat is required in order to control the level of ice 

in the dispenser (Refer to ATTENTION above). Contact your 

icemaker manufacturer to obtain the correct bin thermostat. 

4.  Bin thermostat should be a minimum of 2” below the top 

edge of the dispenser. The preferred location of the bin   

thermostat is on the left side wall. 

Failure to use an ice bin thermostat will not only void 

your IBD’s warranty but will result in the inability to 

control the level of ice in the ice bin which can cause 

damage to your dispenser.

ATTENTION

2.  Rotate the merchandiser, away from the unit, from the  

bottom to disengage from valve block.

4”

Attach Bin Stat Bracket As Shown

Recommended Bin Stat Attachment

Bulb

Tube

Summary of Contents for Sensation 44

Page 1: ...cess or for your convenience scan this QR code with a mobile device app required for immediate access to other Technical Documents and alternative translations if available pertaining to this unit Con...

Page 2: ...acity 312 lbs 142 kg CARBON DIOXIDE CO2 SUPPLY Min Pressure 70 psi 0 483 MPa Max Pressure 80 psi 0 552 MPa FITTINGS Carbonator Inlet 3 8 inch barb Plain Water Inlet 3 8 inch barb Brand Syrup Inlets 3...

Page 3: ...weight of the dispenser ice and possibly an icemaker being installed after counter cut out is made Total weight with icemaker for this unit could exceed 800 pounds 363 6kg The dispenser should only b...

Page 4: ...r use a bin thermostat to control the ice level see below This will prevent damage to the dispensing mechanism The bracket for mounting a thermostat is located in the ice bin During the automatic agit...

Page 5: ...ubing from the water source to the plain water inlet at the front of the unit and connect tubing to inlet using the oetiker pliers and fittings see Plumbing Diagrams on the front of the unit or on pag...

Page 6: ...nts as condensation will form CAUTION Pouring hot water down the drain may cause the Drain Tube to collapse Allow only luke warm or cold water to enter the Drain Tube Pouring coffee tea or other simil...

Page 7: ...just both of the low pressure regulators on the regulator manifold to 75 psi 0 517 MPa then tighten locknut with wrench 11 Activate each valve until gas out 12 Plug in the remote carbonator pump deck...

Page 8: ...quired to remove the merchandiser to gain access to valves NOTE 8 Using a Lancer ratio cup activate the valve and capture a sample Verify that the syrup level is even with the water level Use a screwd...

Page 9: ...mum of five gallons of cleaning solution Do not use abrasive cleaners or solvents because they can cause permanent damage to the unit Ensure rinsing is thorough using clean potable water at a temperat...

Page 10: ...on page 9 thoroughly wipe down the flavor injector nozzle and bracket then let air dry DO NOT rinse with water after sanitizing 6 Repeat Steps 2 5 for second flavor injector nozzle 7 Connect power 8...

Page 11: ...om Ice Chute link by pushing pin through shaft until link is free Pin shown in out position A B C A Agitator Clip Pin B Hub C Agitator Bar 22 Remove the Agitator bar and Hub from the Ice Bin 23 Remove...

Page 12: ...warm water and flush out syrup remaining in the lines 4 Prepare Cleaning Solution described on previous page 9 5 Place syrup lines with BIB connectors into cleaning solution 6 Activate each valve unt...

Page 13: ...13 PLUMBING DIAGRAM Sensation 44 Unit Plumbing Diagram Sensation 44 Flavor Shot Box Plumbing Diagram...

Page 14: ...14 WIRING DIAGRAMS Wiring Diagram 115 Volt...

Page 15: ...15 Wiring Diagram 220 240 Volt...

Page 16: ...6 7 6 2 2 3 8 3 4 7 4 5 SW1 SWITCH 1 NOT USED FOR MODEL 4900 ON 5 4 SWITCH AGITATOR ON TIME 5 6 OFF OFF 11 SECONDS OFF ON 9 SECONDS ON OFF 7 SECONDS ON ON 5 SECONDS SWITCH AUGER RUN TIME 7 8 OFF OFF 6...

Reviews: