S8H Hi-Carb Superchiller 

230V / 50Hz                                                                                       

 

 

www.lancerbeverage.com 

Page 5 of 28 

Hoshizaki Lancer reserve the right to change specifications without notice. 

Part No: 68000036 

Images are for illustration purposes only as product may vary. 

No. 111 

– 4 Apr 22 

 

Review all applicable WHS (Work Health & Safety) regulations. 

 

Review all applicable Beverage Dispensing Gas Standards  

 

Learn how to operate the Superchiller and use the controls properly. 

 

Do not allow untrained personnel to operate the machine.  

 

Ensure that the Superchiller is maintained according to service manual instructions.  

 

Do not allow any unauthorised modifications to the machine. 

 

2.2

 

Recognise Safety Alert Symbols 

The safety alert symbol precedes Warning and Caution notes throughout this manual. To 
prevent personal injury or damage to the machine these alerts must be strictly adhered too. 

 

 

Warning 

Alerts to a potentially hazardous situation that if not avoided CAN result in 
death, serious injury. 

 

 

Caution 

Alerts to a potentially hazardous situation that if not avoided MAY result in 
injury or equipment damage. 

 

 

Warning 

Risk of fire. 

 

2.3

 

Operating 

 

Warning 

Superchillers are intended for indoor operation only; do not operate outside 
unless suitably protected by a weatherproof enclosure. This appliance is not 
suitable for installation in an area where a water jet could be used. 

 

 

Caution 

This appliance is not intended for use by persons (including children) with 
reduced physical, sensory or mental capabilities, or lack of experience and 
knowledge, unless they have been given supervision or instruction concerning 
use of the appliance by a person responsible for their safety.  Children should 
be supervised to ensure that they do not play with the appliance. 

 

 

Caution 

This appliance is intended to be used in commercial applications such as 
restaurants or similar. 

 
 
 

2.4

 

Service & Maintenance 

 

Caution 

Installation of Superchiller and service work should only be performed by fully 
trained & certified Electrical, Plumbing, & Refrigeration Technicians. 
 
In Queensland a gas work licence (hydrocarbon refrigerant) is required to 
undertake gas work on the gas system of a gas device in Queensland that 
uses fuel gas as a refrigerant such as charging, discharging or breaking into a 
refrigeration system.

 

 

Summary of Contents for S8H

Page 1: ...www lancerbeverage com S8H Hi Carb Superchiller 230V 50Hz Installation Operation Service Manual...

Page 2: ...lancerbeverage com Page 2 of 28 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000036 Images are for illustration purposes only as product may vary No 111 4 Apr 2...

Page 3: ...hon 8 3 5 Connecting to water supply 9 3 6 Plumbing the drain and CO2 Exhaust 10 3 7 Connecting to CO2 supply 10 3 8 Filling the waterbath 10 3 9 Electrical Connection 10 3 10 Commissioning 11 3 11 Pu...

Page 4: ...Shipping 173 kg 185 kg Empty 161 kg 173 kg Operating 341 kg 353 kg Refrigerant 145 grams R290 x 2 Ice bank Weight 75 kg Water Bath Capacity 180 litres Construction Stainless Steel Compressor Secop x 2...

Page 5: ...ded MAY result in injury or equipment damage Warning Risk of fire 2 3 Operating Warning Superchillers are intended for indoor operation only do not operate outside unless suitably protected by a weath...

Page 6: ...osting process other than those recommended by the manufacturer Warning Do not damage the refrigeration circuit In Queensland a gas work licence hydrocarbon refrigerant is required to undertake gas wo...

Page 7: ...lt the chiller more than 45 degrees or lay chiller on its side 3 3 Selecting a Location Warning Superchillers are intended for indoor operation only do not operate outside unless suitably protected by...

Page 8: ...xed to floors or walls 3 4 Connecting Python Caution NOTE The S8H Superchiller is rated to operate with a maximum of 30m of python connected at 40 C 45m at 32 C per carbonation circuit Exceeding manuf...

Page 9: ...circuit out and back from dispense point to soda return 3 5 Connecting to water supply Warning The connections to the mains water supply must be made in accordance with the Plumbing Code of Australia...

Page 10: ...to not splash water onto the electrical components Check that the Superchiller is unplugged from the mains electrical supply Remove the top panel Fill the water tank with water up to the FILL LEVEL ma...

Page 11: ...dispensing valve or Bargun connected to the Superchiller systems until an uninterrupted flow of soda water where applicable and syrup pours from each dispenser 3 12 LED Display Panel FUNCTION DESCRIPT...

Page 12: ...es ensure work areas are clean and tidy The Superchiller supplies soda water to the dispensing valves barguns To ensure optimum drink quality and system performance at all times please follow cleaning...

Page 13: ...rchiller and its associated beverage system components must be thoroughly cleaned and sanitised annually Prepare sanitising solution Prepare sanitising solution in accordance with the manufacturer s w...

Page 14: ...om Page 14 of 28 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000036 Images are for illustration purposes only as product may vary No 111 4 Apr 22 5 Postmix Cir...

Page 15: ...ncerbeverage com Page 15 of 28 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000036 Images are for illustration purposes only as product may vary No 111 4 Apr 22...

Page 16: ...www lancerbeverage com Page 16 of 28 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000036 Images are for illustration purposes only as product may vary No 111 4...

Page 17: ...ice bank control contacts remain closed Liquid Line temperature probe failure Dirty condenser Restricted air flow over unit Low supply voltage Defective thermal overload Check wiring connections Fan m...

Page 18: ...demand Tube burst valve open downstream Blocked vented backflow preventer Coil freeze up Worn defective pump Failed carbonator probe circuit Check filters taps and supply tubing for blockages and rect...

Page 19: ...overload Carbonator flooded filled completely with water Ensure of adequate water supply Switch should close above 140 kpa Replace if defective Replace motor Replace pump Excessive mains water pressu...

Page 20: ...the centre terminal Refrigeration system should continue to operate Simulates ice growth over green probe Water still contacting red and black probes 4 Remove the remaining jumper The compressor relay...

Page 21: ...No 68000036 Images are for illustration purposes only as product may vary No 111 4 Apr 22 9 Assembly Diagrams Parts Lists 9 1 Postmix Assembly Diagram 9 2 Postmix Parts List Ref Part No Description 1...

Page 22: ...BARB 21 79001259 WASHER NYLON 10 X 19 X 1 5MM 22 83000543 SWITCH PRESSURE NO BRASS CO2 415 KPA 23 79000346 UBEND 10MM 1 X 10MM TAKEOFF 24 79152855 TUBE TO HOSE STEM 3 8 X 3 8 JG 25 79151942 EQUAL STR...

Page 23: ...ry No 111 4 Apr 22 9 3 Refrigeration Assembly Diagram 9 4 Refrigeration Parts List Ref Part No Description 1 62000230 EVAPORATOR ASSY S8H 2 84000034 CONDENSER 1 5KW R290 3 87000158 DRIER COPPER XH7 10...

Page 24: ...SFR 2 83000656 HARNESS TSFR DRIVE 2M 3 83000562 TIMER RELAY ON DELAY 4 83000670 HARNESS IB PROBE ON DELAY 5 83000470 CONTROLLER OMNI EXTRA 6 83000948 EMI FILTER FN 2030A 20 08 7 83000671 LEAD POWER 15...

Page 25: ...w lancerbeverage com Page 25 of 28 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000036 Images are for illustration purposes only as product may vary No 111 4 Ap...

Page 26: ...01291 PANEL REF DECK SUPPORT S8H 8 61001284 DIVIDER PANEL S8H 61001297 BRACKET REF DECK S8H 9 61002163 PANEL BASE ASSY S8H 10 61001292 PANEL REAR S8H 11 61001299 PANEL UPPER REAR S8H 12 61001289 PANEL...

Page 27: ...e Divisional Sales Manager Lancer may choose to reimburse the customer for some or all labour costs associated with a warranty claim Any claim for labour costs must be authorized by Lancer prior to th...

Page 28: ...ons All pumps run quietly and carbonator pump switched ON OFF Check icebank probe position and tightness and correct wiring of harness Carbonator and plumbing pressure tested Check for leaks on pumps...

Reviews: