S8H Hi-Carb Superchiller
230V / 50Hz
www.lancerbeverage.com
Page 19 of 28
Hoshizaki Lancer reserve the right to change specifications without notice.
Part No: 68000036
Images are for illustration purposes only as product may vary.
No. 111
– 4 Apr 22
Faulty low pressure switch (if fitted).
Defective motor.
Locked up pump. Motor has cut out
on overload.
Carbonator flooded
– filled
completely with water.
Ensure of adequate water supply. Switch
should close above 140 kpa. Replace if
defective.
Replace motor.
Replace pump.
Excessive mains water pressure - must be at
least 175 - 345 kpa max.
(Install water
pressure regulator if necessary)
Empty CO2 cylinder. Replace and check
reulator settings to 550 kPa
Faucet delivers CO2
gas continuously.
Low water supply.
Excessive CO2 Pressure.
See: Pump(s) Will Not Run
Check Carbonator CO
2
pressure regulator for
creeping. It should be set at 550 kpa.