background image

S8H Hi-Carb Superchiller 

230V / 50Hz                                                                                       

 

 

www.lancerbeverage.com 

Page 22 of 28 

Hoshizaki Lancer reserve the right to change specifications without notice. 

Part No: 68000036 

Images are for illustration purposes only as product may vary. 

No. 111 

– 4 Apr 22 

79000316 

 

TEE SS 6MM BARB 

79000239 

 

CROSS BARB 6MM SS 

08000002 

 

CARBONATOR RELIEF VALVE 

23000035 

 

CARBONATOR 2.5L 

10 

23000022 

 

PROBE WASHER 

11 

23521975 

 

CARB PROBE 

12 

79158146 

 

SEAL NYLON FLARE ¼ 

13 

79000272 

 

FITTING 10MM BARB 1/4FL SWL 

14 

79655294 

 

FLARE SEAL MODIFIED ¼ YE 

15 

79000335 

 

ELBOW SWIVEL 6MM X ¼ FL 

16 

16170469 

 

FTG ASSY CO2 FLARE 

17 

87000071 

 

TAIL SS 6MM BARB ¼ NUT 

 

79000205 

 

NUT SWIVEL ¼ FL NICKEL 

18 

79117818 

 

TAIL SS 10MM BARB 3/8 NUT 

 

79000206 

 

NUT SWIVEL 3/8 FL NICKEL 

19 

79158134 

 

SEAL NYLON FLARE 3/8 

20 

79001257 

 

TEE SS 6 BARB X 1/8BSPF X 6 BARB 

21 

79001259 

 

WASHER NYLON 10 X 19 X 1.5MM 

22 

83000543 

 

SWITCH PRESSURE NO BRASS CO2 415 KPA 

23 

79000346 

 

UBEND 10MM 1 X 10MM TAKEOFF 

24 

79152855 

 

TUBE TO HOSE STEM 3/8 X 3/8 JG 

25 

79151942 

 

EQUAL STRAIGHT CONNECTOR 3/8 JG 

26 

83000547 

 

FLOWMETER ASSY 0.5 

– 10 LPM 

27 

83000544 

 

SWITCH PRESSURE NO SS H2O 140 KPA 

28 

79001258 

 

TEE SS 10 BARB X 1/8BSPF X 10 BARB 

29 

79001211 

 

NUT JAM SS 5/8-18 UNF 

30 

79001210 

 

FTG BULKHEAD 1/2BSPF X 10 BARB 

31 

79000894 

 

CHECK VALVE DUAL ½” 

32 

80000191 

 

MOTOR AGITATOR EC 650/1200 RPM 12W 

33 

61600008 

 

AGI BRACKET ASSY S8E 

34 

87000144 

 

BLADE AGITATOR 36119 X ¼ BSW 

35 

79001212 

 

INSULATOR ASSY TM/TSFR PUMP 

 

79001213 

 

STRAP HOOK & LOOP 25MM X 600MM 

36 

78000103 

 

PUMP BLDC VAR SP TSFR 

 

78000134 

 

PUMP ONLY TSFR 

 

80000253 

 

MOTOR ONLY TSFR 

37 

79000337 

 

FITTING SS 10MM BARB X 3/8 NPT 

38 

79001099 

 

BACKFLOW ABCO 3/8NPT X 3/8FL 38  

39 

78000101 

 

PUMP FOT BRASS 

40 

78000020 

 

BRASS DRIVE KEY 

41 

80000106 

 

MOTOR PMIX FASCO KEY 

43 

61001319 

 

PROBE HOLDER WATERBATH 

44 

83000091 

 

PROBE NTC015HP00 CAREL 

 

 

Summary of Contents for S8H

Page 1: ...www lancerbeverage com S8H Hi Carb Superchiller 230V 50Hz Installation Operation Service Manual...

Page 2: ...lancerbeverage com Page 2 of 28 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000036 Images are for illustration purposes only as product may vary No 111 4 Apr 2...

Page 3: ...hon 8 3 5 Connecting to water supply 9 3 6 Plumbing the drain and CO2 Exhaust 10 3 7 Connecting to CO2 supply 10 3 8 Filling the waterbath 10 3 9 Electrical Connection 10 3 10 Commissioning 11 3 11 Pu...

Page 4: ...Shipping 173 kg 185 kg Empty 161 kg 173 kg Operating 341 kg 353 kg Refrigerant 145 grams R290 x 2 Ice bank Weight 75 kg Water Bath Capacity 180 litres Construction Stainless Steel Compressor Secop x 2...

Page 5: ...ded MAY result in injury or equipment damage Warning Risk of fire 2 3 Operating Warning Superchillers are intended for indoor operation only do not operate outside unless suitably protected by a weath...

Page 6: ...osting process other than those recommended by the manufacturer Warning Do not damage the refrigeration circuit In Queensland a gas work licence hydrocarbon refrigerant is required to undertake gas wo...

Page 7: ...lt the chiller more than 45 degrees or lay chiller on its side 3 3 Selecting a Location Warning Superchillers are intended for indoor operation only do not operate outside unless suitably protected by...

Page 8: ...xed to floors or walls 3 4 Connecting Python Caution NOTE The S8H Superchiller is rated to operate with a maximum of 30m of python connected at 40 C 45m at 32 C per carbonation circuit Exceeding manuf...

Page 9: ...circuit out and back from dispense point to soda return 3 5 Connecting to water supply Warning The connections to the mains water supply must be made in accordance with the Plumbing Code of Australia...

Page 10: ...to not splash water onto the electrical components Check that the Superchiller is unplugged from the mains electrical supply Remove the top panel Fill the water tank with water up to the FILL LEVEL ma...

Page 11: ...dispensing valve or Bargun connected to the Superchiller systems until an uninterrupted flow of soda water where applicable and syrup pours from each dispenser 3 12 LED Display Panel FUNCTION DESCRIPT...

Page 12: ...es ensure work areas are clean and tidy The Superchiller supplies soda water to the dispensing valves barguns To ensure optimum drink quality and system performance at all times please follow cleaning...

Page 13: ...rchiller and its associated beverage system components must be thoroughly cleaned and sanitised annually Prepare sanitising solution Prepare sanitising solution in accordance with the manufacturer s w...

Page 14: ...om Page 14 of 28 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000036 Images are for illustration purposes only as product may vary No 111 4 Apr 22 5 Postmix Cir...

Page 15: ...ncerbeverage com Page 15 of 28 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000036 Images are for illustration purposes only as product may vary No 111 4 Apr 22...

Page 16: ...www lancerbeverage com Page 16 of 28 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000036 Images are for illustration purposes only as product may vary No 111 4...

Page 17: ...ice bank control contacts remain closed Liquid Line temperature probe failure Dirty condenser Restricted air flow over unit Low supply voltage Defective thermal overload Check wiring connections Fan m...

Page 18: ...demand Tube burst valve open downstream Blocked vented backflow preventer Coil freeze up Worn defective pump Failed carbonator probe circuit Check filters taps and supply tubing for blockages and rect...

Page 19: ...overload Carbonator flooded filled completely with water Ensure of adequate water supply Switch should close above 140 kpa Replace if defective Replace motor Replace pump Excessive mains water pressu...

Page 20: ...the centre terminal Refrigeration system should continue to operate Simulates ice growth over green probe Water still contacting red and black probes 4 Remove the remaining jumper The compressor relay...

Page 21: ...No 68000036 Images are for illustration purposes only as product may vary No 111 4 Apr 22 9 Assembly Diagrams Parts Lists 9 1 Postmix Assembly Diagram 9 2 Postmix Parts List Ref Part No Description 1...

Page 22: ...BARB 21 79001259 WASHER NYLON 10 X 19 X 1 5MM 22 83000543 SWITCH PRESSURE NO BRASS CO2 415 KPA 23 79000346 UBEND 10MM 1 X 10MM TAKEOFF 24 79152855 TUBE TO HOSE STEM 3 8 X 3 8 JG 25 79151942 EQUAL STR...

Page 23: ...ry No 111 4 Apr 22 9 3 Refrigeration Assembly Diagram 9 4 Refrigeration Parts List Ref Part No Description 1 62000230 EVAPORATOR ASSY S8H 2 84000034 CONDENSER 1 5KW R290 3 87000158 DRIER COPPER XH7 10...

Page 24: ...SFR 2 83000656 HARNESS TSFR DRIVE 2M 3 83000562 TIMER RELAY ON DELAY 4 83000670 HARNESS IB PROBE ON DELAY 5 83000470 CONTROLLER OMNI EXTRA 6 83000948 EMI FILTER FN 2030A 20 08 7 83000671 LEAD POWER 15...

Page 25: ...w lancerbeverage com Page 25 of 28 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000036 Images are for illustration purposes only as product may vary No 111 4 Ap...

Page 26: ...01291 PANEL REF DECK SUPPORT S8H 8 61001284 DIVIDER PANEL S8H 61001297 BRACKET REF DECK S8H 9 61002163 PANEL BASE ASSY S8H 10 61001292 PANEL REAR S8H 11 61001299 PANEL UPPER REAR S8H 12 61001289 PANEL...

Page 27: ...e Divisional Sales Manager Lancer may choose to reimburse the customer for some or all labour costs associated with a warranty claim Any claim for labour costs must be authorized by Lancer prior to th...

Page 28: ...ons All pumps run quietly and carbonator pump switched ON OFF Check icebank probe position and tightness and correct wiring of harness Carbonator and plumbing pressure tested Check for leaks on pumps...

Reviews: