background image

42

Part No. 

Description

52-4258 

POWER SUPPLY,24VDC,65W

52-4272 

MICROBUS PCB ASSY

52-4326/01 

HARNESS,MIKROBUS TO KS

52-4329 

HARNESS ASSY,VALVE,LEFT

64-5037/01 

PCB ASSY,ICE CONTROL BD

64-6036 

PCB ASSY,UNIV DISPENSE

81-0371/01 FAN,ROHS,PANCAKE,24VDC

82-6580 

PANEL ASSY,ADA,TP30

Part No. 

Description

52-4214 

POWER SUPPLY,27V,120W

52-4306 

KEYSWITCH ASSY,TP30

52-4324 

HARNESS,DIO TO ICE,SWITCHES

52-4326 

HARNESS,MIKROBUS TO KS,UDC2

52-4337 

HARNESS,CUP LIGHT,TP30

64-6036

2X

52-4328

52-4329

81-0371/01

52-4258

52-4214

64-5037/01

82-6580

52-4337

52-4306

52-4324

52-4326/01

52-4272

Electrical Assembly

Summary of Contents for IBD Bold 30i

Page 1: ...f Lancer Corp 2021 by Lancer all rights reserved For more Information visit lancerworldwide com or call Tech Support Warranty 800 729 1550 6655 Lancer Boulevard San Antonio TX 78219 custserv lancerwor...

Page 2: ...Electrical Warning 3 CO2 Warning 4 CO2 Safe Handling and Storage 4 Water Notice 5 Automatic Agitation 5 SPECIFICATIONS AND FEATURES 6 7 IBD Bold 30i 6 General Systems Overview Remote Syrup Pumps 7 PRE...

Page 3: ...l ne doit pas tre utilis par des enfants ou des personnes handicap es sans supervision Cet appareil peut tre utilis par des enfants g s de 8 ans et plus et des personnes ayant des capacit s physiques...

Page 4: ...mpting to repair the leak WARNING Strict attention must be observed in the prevention of CO2 gas leaks in the entire CO2 and soft drink system 5 Carbon Dioxide CO2 CO2 cylinders should only be handled...

Page 5: ...ant un surpresseur d eau si n cessaire Installez un filtre dans la conduite d eau pour prot ger l appareil et liminer tout arri re go t Inspectez le filtre eau r guli rement selon les conditions du r...

Page 6: ...8 inch barb Plain Water Inlet 3 8 inch barb Brand Syrup Inlets 3 8 inch barb Ambient Flavor Inlets 3 8 inch barb CO2 Inlet 3 8 inch barb ELECTRICAL 120 VAC 60 Hz 5 0 Amps 220 240 VAC 50 60 Hz 2 5 Amps...

Page 7: ...top support the weight of the dispenser Include the weight of an ice machine plus weight of ice if necessary Is dispenser located away from direct sunlight or overhead lighting TOOLS REQUIRED Oetiker...

Page 8: ...ovided NOTE 4 Remove plywood shipping base from unit by moving unit so that one side is off the countertop or table allowing access to screws on the bottom of the plywood shipping base 5 Remove access...

Page 9: ...le depuis le sol ne doit pas d passer 48 si le point de contact est moins de 10 de l avant du comptoir ou un maximum de 46 si le point de contact est plus moins de 10 et moins de 27 de l avant du comp...

Page 10: ...ions sur un thermostat de bac adapt ATTENTION Failure to use an ice bin thermostat will not only void your IBD s warranty but will result in the inability to control the level of ice in the ice bin wh...

Page 11: ...tions NOTE Since this unit uses ice for cooling there is no risk of water freezing within the tubes in the unit as long as the unit is used indoors and not placed in extreme cold environments NOTE L i...

Page 12: ...rm es L isolation doit couvrir toute la longueur du tuyau de vidange y compris les raccords Le drain doit tre install de mani re ce que l eau ne s accumule pas dans les affaissements ou autres points...

Page 13: ...aux de vidange de la plaque froide sont align s avec les ouvertures du bac d gouttage Assurez vous que l extr mit du tuyau repose au moins un demi pouce sur le bord de l ouverture pour assurer un bon...

Page 14: ...he syrup pumps and to the unit A B C A Syrup Pump Outlet B Syrup Pump C Fitting 4 Connect tubing from dispenser syrup inlet to the syrup pump outlet fitting Repeat for each syrup line pump A Tee Fitti...

Page 15: ...r B Fitting C Line to CO2 Regulator Manifold D Oetiker Pliers A B C D Avant d installer le r gulateur assurez vous qu un joint torique ou une rondelle est en place dans l crou d accouplement du r gula...

Page 16: ...located on the right side of the unit to the vertical position A A Circuit breaker N alimentez jamais la machine s il y a une trace quel conque de dommage Contactez le service la client le de Lancer p...

Page 17: ...old to 75 psi 0 517 MPa then tighten locknut with wrench 8 Purge carbonated water CW buttons until gas out 9 Plug in the remote carbonator pump deck if not already done so and turn the switch to the O...

Page 18: ...o peut tre ajust en appuyant sur les boutons du volet Ratio REMARQUE Ambient flavor valves A1 A8 can be configured as ambient brand valves by pressing and holding the Set to Brand or Set to Flavor but...

Page 19: ...dule 7 See Plumbing Diagram on front of machine or page 44 for reference 8 Repeat steps 5 and 6 until the designated volume is achieved 9 Repeat calibration for the other water modules Graduated Cylin...

Page 20: ...r reference 6 Repeat steps 4 and 5 until the designated volume of 50 ml is achieved 7 Repeat steps 2 6 for the remaining brand syrup modules A B C D Increase Decrease A Flow Control B Valve Retainer C...

Page 21: ...el as instructed by the ratio cup use a screwdriver to adjust the syrup flow control See Plumbing Diagram on page 44 for reference 3 Insert syrup separator into outer nozzle 7 Hold the ratio cup under...

Page 22: ...il n y a pas de produit disponible ou qu il y a un probl me avec la marque sp cifi e et sera distribu lorsqu il est activ Auto signifie que le capteur puis configur contr le si la marque peut tre dist...

Page 23: ...the brands to their desired location Dual Grid mode limits the positioning of brand icons to the associated dispense nozzle that the brand was mapped NOTE Le mode Dual Grid limite le positionnement de...

Page 24: ...n be edited for each playlist The Delete button will erase the playlist and associated media content from the dispenser 4 Ice image can be changed using the ice image selector pane To upload new ice i...

Page 25: ...USB doit tre format en FAT32 REMARQUE 2 For videos create a txt file in any editor software ex Notepad on Windows machines that contains the name of all video files for a playlist The name of the tex...

Page 26: ...r the Import USB Data pane to import new brand icons Note that existing brands can be overwritten or appended if desired 7 Tap the Flavors button under the Import USB Data pane to import new flavor ic...

Page 27: ...debug data for troubleshooting 7 Tap the Update Software button under the Software pane to import the selected software version from USB The following highlights the steps necessary to copy a tower s...

Page 28: ...noid Test Screen 4 Touchscreen will be disabled for 30 seconds for cleaning 6 Tap Start Solenoid Test to begin testing of all valves Depending on the state of the solenoids it may be necessary to tap...

Page 29: ...rcorp portal app cu azurewebsites net It may take up to 10 minutes for a network connection to be established NOTE L tablissement d une connexion r seau peut prendre jusqu 10 minutes REMARQUE 4 Locate...

Page 30: ...ted POWER SOFTWARE AND DATA USER INTERFACE Reset Preferences Restores settings and customization back to default Reset Valve Configuration Clears the valve configuration back to default Reset All Rese...

Page 31: ...rsion Dispenser I O board name and version number Dispense Controller DC1 Version Dispense controller DC1 version number Dispense Controller DC2 Version Dispense controller DC2 version number Software...

Page 32: ...l usine apr s avoir t nettoy s et aseptis s conform ment aux lignes directrices de la National Sanitation Foundation NSF Pour assurer le bon fonctionnement de cet quipement et maintenir les exigences...

Page 33: ...e integrity of the powder coated finish The recommended method for cleaning the powder coated surface is to use warm water and a mild soap such as Windex Dawn 409 etc Certain chemical cleaners such as...

Page 34: ...10 Reinstall the outer nozzle and cover to the unit 11 Repeat Steps 3 10 for the second nozzle A A Nozzle B Nozzle Cover B 1 Disconnect the flavor injector and syrup lines from BIB s 2 Place lines wit...

Page 35: ...dule Water in ice bin 1 Coldplate drain is obstructed 1 Remove splash plate and drip tray to obtain access to drain tubes and clear accordingly Water leakage around nozzle 1 Damaged or improperly inst...

Page 36: ...hut off 1 Solenoid plunger sticking 2 Replace solenoid coil Water continually leaking at connections 1 Loose water connections 2 Flare seal washer leaks 1 Tighten water connections 2 Replace flare sea...

Page 37: ...ing harness not plugged in 5 PC board defective 6 Malfunctioning power supply 1 Connect dispenser to power source 2 Turn key switch to on position 3 Touch screen wait enter code 4 Plug in wiring harne...

Page 38: ...ck BIB connector if still leaking then replace line 2 Replace O ring 3 Replace defective pump BIB pump fails to restart after bag replacement 1 BIB connector not on tightly 2 BIB connector is stopped...

Page 39: ...ics Labels Assembly ILLUSTRATIONS AND PART LISTINGS Part No Description 06 2342 01 Electrical Hazard Warning Label 06 3289 01 Dip Switch Legend Label 06 4131 Plumbing Diagram Label 06 2342 06 3289 01...

Page 40: ...2845 30 16741 01 51 7316 01 2X 20 2000 01 4X 51 7318 01 30 16846 2X 91 0198 2X 49 1000 01 4X 19 1011 18X 19 1010 82 4415 30 11044 91 4008 01 05 0999 01 51 7341 01 05 4285 2X 05 4397 01 05 4391 52 425...

Page 41: ...APPER RT TP30 30 16741 01 WRAPPER LFT TP30 30 16845 01 TOP FRAME TP30 30 16846 BRACKET PILOT TP30 49 1000 NOZZLE ASSY TP30 51 7316 01 BRACKETASSY FRAME LEFT TP30 51 7318 01 BRACKETASSY LINKAGE TP30 51...

Page 42: ...SY UNIV DISPENSE 81 0371 01 FAN ROHS PANCAKE 24VDC 82 6580 PANEL ASSY ADA TP30 Part No Description 52 4214 POWER SUPPLY 27V 120W 52 4306 KEYSWITCH ASSY TP30 52 4324 HARNESS DIO TO ICE SWITCHES 52 4326...

Page 43: ...CB USB B PORT J17 UDC2 COM PORT J7 DIO PCB KEY SWITCH CON J1 USE TOP USB PORT FOR SECURITY KEY INSTALLATION AND USE BOTTOM USB PORT FOR USB A TO USB B CABLE TO DIO PCB POWER SUPPLY HDMI CABLE IS ROUTE...

Page 44: ...4 6 16 8 10 12 14 1 3 5 7 9 NC 11 13 15 NC 1 3 5 15 7 9 11 13 BLK WHT GRY BLK PUR BLU GRN YEL ORG RED BRN VIO BLK BLK GRN BLK BRN BLK ORG BLK BLK BLK GRY PUR BLU GRN YEL ORG RED BRN WHT BLK VIO BLK BL...

Page 45: ...K WHT BLK GRN BLU BLK WHT BLU ICE DOOR SOLENOID WHT Back Front GRN LINE LINE LOAD LOAD DC FAN LCD DISPLAY SBC 27VDC BLOCK BLK BLK WHT WHT RED BLK BLK BLK RED RED RED RED BLK BLK RED RED RED RED RED BL...

Page 46: ...RIGHT VALVEHARN LEFT SBC DIO PCB POWER SUPPLY USB A MALE TO USB A FEMALE DC1 DC2 USB A TO USB B DENOTES DEFAULT 3 2 SW2 SWITCH 2 POSITION DOES NOT MATTER 4 ON LANCER PN 06 3289 01 SW1 5 2 5 8 ON 1 ON...

Page 47: ...8 15 16 34 23 18 5 8 1 5 8 11 1 1 2 3 DIAMETER OPTIONAL 3 9 26 15 11 1 2 2 F R O N T O F D I S P E N S E R OPTIONAL HOLES FOR FASTENING DISPENSER TO COUNTER WITH SCREWS CUT OUT DASHED AREA BOLD COUNT...

Page 48: ...A HOSHIZAKI COMPANY 6655 Lancer Boulevard San Antonio TX 78219 lancerworldwide com...