9. Turn on CO
2
at the source then, using a screwdriver, adjust
the high pressure regulator at the source to 75 PSI (0.517
MPA) then tighten locknut with wrench.
10. Adjust the low pressure regulator routed from the normal,
non-diet syrup pumps and remote chiller to 75 PSI (0.517
MPA).
11. Adjust the second low pressure regulator routed from the
diet syrup pumps to 35 PSI (0.241 MPA).
12. Select the soda button then press and hold the pour/cancel
button until gas out.
13. Reactivate the pump deck at the remote chiller.
14. Repeat Step 12 until a steady flow of soda is achieved.
A. Regulator Adjustment Screw
B. Adjust to 75 PSI (0.517 MPA)
C. Wrench
A. Nozzle
B. Clamp
C. Counter
A. Brand Buttons
B. Soda Button
C. Flavour Injector Buttons
D. Portion Control Buttons
E. Pour/Cancel Button
A
A
A
A
A
A
A
B
B
C
C
C
C
C
Adjust Water Flow Rate & Syrup/Water Ratio
12
The refridgeration unit should have been running for at
least one (1) hour before attempting to set flow rates
on valves. The drink temperature should be no higher
than 40°F (4.4°C) when flow rates are set. This is best
done after the remote chiller has already made an ice
bank.
NOTE
1. Using a Lancer ratio cup verify water flow rate (5 oz. in 4
sec.) by activating the soda module. Remove the protective
cap for the corresponding valve and use a screwdriver to
adjust if needed.
2. Repeat Step 1 for the plain water brand whose syrup was
closed in the previous section.
3. Open the syrup line at the backblock, closed in the previous
section.
4. Once all the water modules have been calibrated, remove
nozzle by twisting counter clockwise and pulling down.
A
A
B
B
C
C
D
D
E
Increase
Decrease
A. Flow Control
B. Valve Retainer
C. Solenoid
D. Valve Body
5. Install Lancer syrup seperator
(PN 82-3458)
in place of
nozzle.
6. Using the keypad, select the brand whose syrup line was
closed in the previous step, then press and hold the pour/
cancel button until a steady flow of water is achieved.
7. Select the soda button then press and hold the pour/cancel
button until a steady flow of water is achieved.
8. Ensure that the pump deck at the remote chiller is turned off
before turning on the CO
2
.