TROUBLE
CAUSE
REMEDY
BIB pump fails to restart after
bag replacement.
1. BIB connector not on tight.
2. BIB connector is stopped up.
3. Kinks in syrup line
4. Bad BIB Pumps.
1. Tighten BIB connector.
2. Clean out or replace BIB connector.
3. Straighten or replace line.
4. Replace BIB pump.
BIB pump fails to restart when
dispensing valve is closed.
1. Leak in discharge line or fittings.
2. Empty BIB.
3. Air leak on inlet line or bag connector.
1. Repair or replace discharge
2. Replace BIB.
3. Repair or replace.
No product out light.
1. Burned-out lamp
2. Faulty wiring or pressure switch in product
line.
1. Replace lamp.
2. Repair or replace.
Low or no carbonation.
1. Low or no CO
2
.
2. Excessive water pressure.
3. Worn or defective carbonator pump.
1. Check CO
2
supply. Adjust CO
2
pressure to
70 PSI (0.483 MPA).
2. Water regulator should be set at 50 PSI
(0.345 MPA)
3. Replace carbonator pump.