1. INSTALLATION OF LANCER TEA DISPENSER
1.1
RECEIVING
Each unit is completely tested under operating conditions and thoroughly inspected before
shipment. At the time of shipment, the carrier accepts the unit, and any claim for damage must be
made with the carrier. Upon receiving unit(s) from the delivering carrier, carefully inspect carton(s)
for visible indication(s) of damage. If damage exists, have carrier note the same on the bill of
lading and file a claim with the carrier.
1.2
UNPACKING
A. The Lancer Tea Dispenser is shipped in a corrugated shipping carton.
B. Carefully remove the corrugated shipping carton.
C. Check to see that the following items are included:
•
Tea Dispenser
•
Remote Transformer
•
Installation Kit
D. Inspect items for concealed damage. If evident, notify delivering carrier and file a claim against
same.
1.3
SELECTING A COUNTER LOCATION
A. Select a counter location which is close to a properly grounded electrical outlet, and a water
supply that meets the requirements specified in Section 1.4 below.
1.4
WATER SUPPLY
A. The dispenser requires a minimum water flowing pressure of 40 PSI.
B. Water pipe connections and fixtures directly connected to a potable water supply shall be sized,
installed, and maintained according to federal, state and local laws.
1.5
ELECTRICAL SUPPLY
WARNING
THE POWER SUPPLY MUST BE PROPERLY ELECTRICALLY GROUNDED TO AVOID
POSSIBLE ELECTRICAL SHOCK OR SERIOUS INJURY TO THE OPERATOR. THE POWER
CORD IS PROVIDED WITH A THREE PRONG GROUNDED PLUG. IF A THREE-HOLE
GROUNDED ELECTRICAL OUTLET IS NOT AVAILABLE, USE AN APPROVED METHOD TO
GROUND THE UNIT.
A. The dispenser requires connection to a properly grounded electrical source: 115V, 60HZ (for
PN 85-1711) or 230V, 50HZ (for PN 85-1712).
NOTE
In the event more than one dispenser is installed, each dispenser should be on a separate 15
amp fused circuit.
B. Power is supplied to each dispenser by the remote transformer (included in Installation Kit)
which converts 115V (for PN 85-1711) or 230V (for PN 85-1712) to 24 VAC.
1.6
INSTALLATION
A. Place Tea Dispenser on counter top. Lay Tea Dispenser on its side to expose product supply
and electrical connections.
B. Identify supply connections in channel on underside of base. The water connection is a 3/8"
barb fitting, and the syrup connection is a 3/8" barb fitting.
C. Thoroughly flush all incoming lines before connecting (see Section 3.3, Cleaning and Sanitizing
Procedure). Avoid putting excessive strain on the lines to the unit; use sufficient line lengths.
D. Identify electrical connector in channel on underside of base.
E. Connect dispenser connector to output of remote transformer.
F. Connect input cord on remote transformer to properly grounded electrical source.
G. Turn Tea Dispenser upright and place in desired location.
1