background image

TABLE OF CONTENTS

SPECIFICATIONS ...................................................................................................................................COVER

TABLE OF CONTENTS ......................................................................................................................................i

MANUFACTURER’S INTRODUCTION ..............................................................................................................i

1. INSTALLATION ...........................................................................................................................................1

1.1

RECEIVING........................................................................................................................................1

1.2

UNPACKING ......................................................................................................................................1

1.3

SELECTING LOCATION....................................................................................................................1

1.4

PLUMBING.........................................................................................................................................1

1.5

ELECTRIC POWER SUPPLY ............................................................................................................2

1.6

SYSTEM CHECK ...............................................................................................................................2

2. START UP, PERIODIC MAINTENANCE, CHECKLIST, AND CLEANING GUIDE ....................................2

2.1

CLEANING AND SANITIZING INSTRUCTIONS ...............................................................................2

2.2

PERIODIC MAINTENANCE, CHECKLIST, AND CLEANING GUIDE ...............................................3

2.3

CLEANING AND SANITIZING BEVERAGE COMPONENTS - FIGAL SYSTEMS............................4

2.4

CLEANING AND SANITIZING BEVERAGE COMPONENTS - BAG-IN-BOX SYSTEMS.................5

3. HOW TO OPERATE THE LANCER MB-18................................................................................................6

3.1

NORMAL OPERATION ......................................................................................................................6

3.2

PROGRAMMING AND SETUP SOFTWARE.....................................................................................6

4. MB-18 TROUBLESHOOTING GUIDE ........................................................................................................8

4.1

PUSH ICE LEVER/CHUTE/ICE BUTTON AND NOTHING HAPPENS.............................................8

4.2

PUSH CHUTE MOTOR RUNS BUT NO ICE DISPENSES...............................................................8

4.3

VALVES DO NOT OPERATE.............................................................................................................8

4.4

WATER IN ICE BIN ............................................................................................................................8

5. ILLUSTRATIONS, PARTS LISTINGS, AND WIRING DIAGRAMS ............................................................8

MB18 SERVICE PARTS

..............................................................................................................................8

BIN ASSEMBLY .................................................................................................................................8

AGITATOR MOTOR ASSEMBLY .......................................................................................................8

AUGER ASSEMBLY...........................................................................................................................9

ICE CHUTE ASSEMBLY ....................................................................................................................9

TOWER ASSEMBLY ..........................................................................................................................9

SHROUD ASSEMBLY......................................................................................................................10

FINAL ASSEMBLY ...........................................................................................................................10

POWER SUPPLY ASSEMBLY.........................................................................................................10

i

MANUFACTURERS INTRODUCTION

High Volume Free Standing Fountain Drink Dispenser

The unit is designed with the highest quality components to be user and service friendly.  Most set up 
parameters are easily set via a serial interface and an infrared wireless data port.  All control is handled by the
on board microprocessor controller.  The 

MB-18

is designed to seamlessly interface with the 

Lancer IceLink

system to provide for a minimum of labor and maintenance by store personnel.

The MB-18 features multiple speed ice dispense from an under counter ice storage bin which is also used to
chill the product utilizing a flexible, high performance cold plate system.  Up to 18 independent brands may be
dispensed through six (6) Lancer Multi-Flavor dispense nozzles.  In addition, 12 ambient (non-chilled) "bonus"
flavors may be added to the drink via the flavor injection system on four (4) nozzles.  Up to three (3) flavors
may be added to each of four (4) nozzle positions.  

The bonus flavors are plumbed independently to each of the

nozzles allowing for a multitude of customer pleasing drink combinations.

Supplier Name: Lancer
Address:

6655 Lancer Blvd 
San Antonio, TX 78219

Phone:

(800) 729-1500

Local Service Name:

Local Service Phone #:

Summary of Contents for 85-10018-126

Page 1: ...ounds 240 kg Operating 800 pounds 363 kg ELECTRICAL Operating Voltage 115 Hertz 60 Amps 20 This initial draft issue is released for field test purposes ONLY DATE 06 18 01 P N 28 0466 6655 LANCER BLVD...

Page 2: ...PPLY ASSEMBLY 10 i MANUFACTURERS INTRODUCTION High Volume Free Standing Fountain Drink Dispenser The unit is designed with the highest quality components to be user and service friendly Most set up pa...

Page 3: ...ater supply must be protected by means of an air gap a backflow prevention device located upstream of the CO2 injection system or another approved method to comply with NSF standards A backflow preven...

Page 4: ...ng ground convenience outlet having the same configuration as the power cord B Outlet must have proper voltage cycles and ampere ratings See Dispenser Name Plate for ratings NOTE Do not plug into elec...

Page 5: ...E Extended lengths of product lines may require that an additional volume of cleaning solution be prepared 2 Sanitizing solutions should be prepared in accordance with the manufacturer s written recom...

Page 6: ...Take care to carefully lift the tower shroud out of the way of the auger tube 4 Remove the auger tube in a similar fashion by lifting it straight up and out of the bin g Remove the Agitator Wheel Ass...

Page 7: ...at least 30 minutes M Disconnect CO2 supply hose from the tank N Reconnect syrup lines to syrup containers for example quick disconnects figal containers etc and ready unit for operation O Draw drink...

Page 8: ...d select keypad on the left hand side of machine ice speed defaults to middle selection if not otherwise selected Selection light will indicate choice C Fill cup with desired amount of ice D Place cup...

Page 9: ...stment STIR is for the auger stir speed and is also requires a setting of 1 through 10 b AUGER SWITCH MENU The auger switch menu selects whether the cup lever or the push buttons initiate ice dispensi...

Page 10: ...se is kinked B Replace Drain Hose Light Emitting Diodes LEDs are provided on the PC Board to aid in troubleshooting electrical difficulties Referring to the wiring diagram included in this manual also...

Page 11: ...375 2 MOUNT BRKT TO MOTOR ICE CHUTE ASSEMBLY 05 0925 CHUTE IBD 1 54 0191 TUBE PRINTED IBD 1 05 0999 LEVER CHUTE IBD 1 05 1488 RESTRICTOR CHUTE IBD 1 12 0244 SWITCH CHUTE 1 04 0268 SCREW 6 19 X 625 1 H...

Page 12: ...Y SYRUP J3 1 VALVES 33 THRU 39 52 2383 WIRE ASSY RIBBON 2 INTERCONNECT TO CPU 52 2384 WIRE ASSY POWER SUPPLY 1 POWER TO CPU 52 2385 WIRE ASSY ICE DISPENSE 1 ICE CHUTE SWITCH TO INTERCONNECT 52 2386 WI...