background image

9

(Continued from previous page)

AGITATOR MOTOR ASSEMBLY (CONTINUED)
PART NO.

DESCRIPTION

QTY/UNIT

COMMENTS

04-0520

SCREW, 1/4-20 X .50

3

MOUNT MOTOR

10-0463

COUPLING, AGITATOR

1

10-0479

PIN, AGITATOR COUP.

1

AUGER ASSEMBLY

05-1805

CAP, AUGER TUBE, BTM

1

05-0823

BEARING, AUGER

1

04-0310

SCREW, 8-16 X .62

3

MOUNT BEARING TO CAP

27-0073

TUBE, AUGER

1

05-1834

ADAPTER, ICE CHUTE

1

82-2799

AUGER, 42", MB18

1

10-0472

COUPLING, AUGER MOTOR

1

10-0445

PIN, BEARING SHAFT

1

91-0136

MOTOR, AUGER, MB18

1

03-0325

PIN, ROLL, .188 X 1.25

1

AUGER DRIVE PIN

05-1803

CAP, AUGER TUBE, TOP

1

04-1237

SCREW, M6 X 16

4

MOUNT CAP TO MOTOR

10-0465

SHAFT, AUGER DRIVE

1

03-0323

KEY, SQUARE, 5MM

1

MOUNT SHAFT TO MOTOR

03-0324

RING, RETAINING, 1/2"

1

MOUNT SHAFT TO MOTOR

04-0233

WASHER, LOCK, 1/4"

1

MOUNT SHAFT TO MOTOR

04-0033

WASHER, FLAT, 1/4"

1

MOUNT SHAFT TO MOTOR

04-0520

SCREW, 1/4-20 X .50

1

MOUNT SHAFT TO MOTOR

30-8105

BRACKET, AUGER MTR MNT

1

04-0124

WASHER, #6 LOCK

2

MOUNT BRKT TO MOTOR

04-0598

SCREW, 6-32 X .375

2

MOUNT BRKT TO MOTOR

ICE CHUTE ASSEMBLY

05-0925

CHUTE, IBD

1

54-0191

TUBE, PRINTED, IBD

1

05-0999

LEVER, CHUTE, IBD

1

05-1488

RESTRICTOR, CHUTE, IBD

1

12-0244

SWITCH, CHUTE

1

04-0268

SCREW, 6-19 X .625

1

HOLDS SWITCH IN CHUTE

03-0241

SPRING, CHUTE, IBD

1

05-0948

CHUTE, DOOR, IBD

1

05-0928

DOOR, CHUTE, IBD

1

10-0234

SHAFT, CHUTE DOOR

1

05-0359

BUSHING

2

MOUNTS SHAFT IN CHUTE

03-0113

RING, RETAINING

2

MOUNTS SHAFT IN CHUTE

TBD

CHUTE MNT SCREW

4

MUST CHANGE PER NSF

TOWER ASSEMBLY

54-0289

NOZZLE ASSY

6

04-0224

SCREW, 6-32 X .25

24

4 PER NOZZLE

05-1612

FITTING ASSY, WATER

30

SYRUP FITTING IN NOZZLE

05-1736

PLUG, M/F NOZZLE

18

FOR UNUSED SYRUP INLETS

02-0214

O-RING

96

2 PER SYRUP AND PLUG FITTINGS

01-0012

ADAPTER, 1/4BRB X DOLE

6

WATER/SODA FITTING IN NOZZLE

02-0005

O-RING

12

2 PER WATER FITTING

82-2713/01

BLOCK, MNT, SINGLE

39

04-1089

SCREW, 10-32 X 1

78

2 PER BLOCK

19-0260

VALVE ASSY, SYRUP

18

19-0261

VALVE ASSY, WATER

9

19-0262

VALVE ASSY, INJ.

12

05-1385

FITTING, SODA/WATER OUT

9

SODA VALVE OUTLET ELL

05-1866

FITTING, OUTLET, SODA

30

SYRUP VALVE OUTLET ELL

02-0089

O-RING

78

2 PER VALVE OUTLET

01-1280

FITTING, TEE, 1/4 BARB

3

TEE SODA & WATER ON 3,4 & 5

(Continued next page)

Summary of Contents for 85-10018-126

Page 1: ...ounds 240 kg Operating 800 pounds 363 kg ELECTRICAL Operating Voltage 115 Hertz 60 Amps 20 This initial draft issue is released for field test purposes ONLY DATE 06 18 01 P N 28 0466 6655 LANCER BLVD...

Page 2: ...PPLY ASSEMBLY 10 i MANUFACTURERS INTRODUCTION High Volume Free Standing Fountain Drink Dispenser The unit is designed with the highest quality components to be user and service friendly Most set up pa...

Page 3: ...ater supply must be protected by means of an air gap a backflow prevention device located upstream of the CO2 injection system or another approved method to comply with NSF standards A backflow preven...

Page 4: ...ng ground convenience outlet having the same configuration as the power cord B Outlet must have proper voltage cycles and ampere ratings See Dispenser Name Plate for ratings NOTE Do not plug into elec...

Page 5: ...E Extended lengths of product lines may require that an additional volume of cleaning solution be prepared 2 Sanitizing solutions should be prepared in accordance with the manufacturer s written recom...

Page 6: ...Take care to carefully lift the tower shroud out of the way of the auger tube 4 Remove the auger tube in a similar fashion by lifting it straight up and out of the bin g Remove the Agitator Wheel Ass...

Page 7: ...at least 30 minutes M Disconnect CO2 supply hose from the tank N Reconnect syrup lines to syrup containers for example quick disconnects figal containers etc and ready unit for operation O Draw drink...

Page 8: ...d select keypad on the left hand side of machine ice speed defaults to middle selection if not otherwise selected Selection light will indicate choice C Fill cup with desired amount of ice D Place cup...

Page 9: ...stment STIR is for the auger stir speed and is also requires a setting of 1 through 10 b AUGER SWITCH MENU The auger switch menu selects whether the cup lever or the push buttons initiate ice dispensi...

Page 10: ...se is kinked B Replace Drain Hose Light Emitting Diodes LEDs are provided on the PC Board to aid in troubleshooting electrical difficulties Referring to the wiring diagram included in this manual also...

Page 11: ...375 2 MOUNT BRKT TO MOTOR ICE CHUTE ASSEMBLY 05 0925 CHUTE IBD 1 54 0191 TUBE PRINTED IBD 1 05 0999 LEVER CHUTE IBD 1 05 1488 RESTRICTOR CHUTE IBD 1 12 0244 SWITCH CHUTE 1 04 0268 SCREW 6 19 X 625 1 H...

Page 12: ...Y SYRUP J3 1 VALVES 33 THRU 39 52 2383 WIRE ASSY RIBBON 2 INTERCONNECT TO CPU 52 2384 WIRE ASSY POWER SUPPLY 1 POWER TO CPU 52 2385 WIRE ASSY ICE DISPENSE 1 ICE CHUTE SWITCH TO INTERCONNECT 52 2386 WI...