10
DO NOT PLUG UNIT INTO GROUNDED ELECTRICAL
OUTLET AT THIS TIME.
Make sure that all water lines
are tight and unit is dry before making any electrical
connections
!
WARNING
Drain line must be insulated with a closed cell
insulation. Insulation must cover the entire length of
the drain hose, including fittings. The drain should be
installed in such a manner that water does not collect
in sags or other low points, as condensation will form.
!
CAUTION
Pouring hot water down the drain may cause the Drain
Tube to collapse. Allow only luke warm or cold water to
enter the Drain Tube.
Pouring coffee, tea, or other
similar substances down the drain may cause the Drain
Tube to become clogged.
!
ATTENTION
4. Connect tubing to water source then flush water lines to
check for leaks.
5. Install water regulator and filter to water line and, if
necessary, install water booster (Lancer PN MC-163172)
between water supply and the unit.
6. Using tubing cutters, cut soda water line and install remote
carbonator per manufacturer’s specifications.
7. Install a shut-off valve in the water line feeding the
carbonator pump deck.
10. Route drain hose from designated open type drain to fitting
below unit and connect hose to fitting.
A
B
A. Oetiker Pliers
B. Tubing
C. Syrup/Water Inlet
C
3. Route appropriate tubing from the water source to the soda
water inlet on the left of the unit and connect tubing to inlet
using the oetiker pliers and fittings, (see Plumbing Diagrams
on the front of the unit or on pages 8-9 for reference).
8. Route appropriate tubing from the syrup pump location to the
syrup inlets and connect tubing to all syrup inlets.
9. Route the power supply cord to a grounded electrical outlet
of the proper voltage and amperage rating.
1. Connect high pressure CO
2
regulator assembly to CO
2
cylinder or bulk system.
-
Thread regulator nut on to tank, then
tighten nut with wrench
A. CO
2
Regulator
B. Outlet
C. Wrench
D. CO
2
Supply
A
B
C
D
Before installing regulator, assure that a seal (washer
or o-ring) is present in regulator attachment nut.
!
ATTENTION
A. High Pressure CO
2
Regulator
B. 1/4” Nut, Stem & Seal
C. Line to Low Pressure
Regulator
D. Oetiker Pliers
A
B
C
D
A dedicated CO
2
regulator is required to supply the
carbonator as well as to all syrup pumps.
!
ATTENTION
Installing CO
2
Supply
2. Connect a 1/4” nut, stem and seal to CO
2
regulator outlet.
3. Route tubing from the 1/4” nut, stem on the high pressure
CO
2
regulator attached to low pressure regulator.