Safety information: XL 8

8 m Telescopic Lance Series

Warning:

3.1. During transport ensure equipment is stored in protective carry case. 

3.2. Do not operate the appliance when other people are in the workspace.

3.3. Store equipment and chemicals in a safe place, with end- caps and plugs in place, away from children and 

animals. 

3.4. When the lance is passed onto third parties, it must be accompanied by the operating instructions.

3.5.  Please  observe  during  operation,  that  the  application  of  pesticides/  insecticides  is  accordance  with  any      

statutory protection acts. 

3.6. Use of the lance against or during strong wind may cause damage.

Application:

2.1. The equipment can be used to spray the industry recognised insecticides, pesticides, weed killers and liquid 

fertilizers, as used in the home, in the garden, on the farm, or in vineyards. Do not use oils. 

Safety Guidelines:

4.1. Make sure that the product you wish to apply is suitable for this equipment. The data safety and handling         

instructions  provided  by  the  chemical  manufacturer  must  be  noted  and  observed.  The  use  of  chemicals  is               

entirely at the user’s own risk. Should you have any doubts in this respect please contact the distributor where 

you purchased your product. 

4.2. The lance must not be used with oil substances, caustic substances (e.g. disinfectants or impregnating liquids 

which attack the skin or materials), corrosive substances (acids) or highly flammable or combustible substances. 

4.3. Before each use, check to ensure that the lance has been correctly assembled, and that it is in a functional 

and undamaged condition. Damaged parts must never be used. 

4.4. To the knowledge of the producer, at the time of manufacturing the unit, the approved pesticide/ insecticide 

will cause no damage to the materials used to create the appliance. 

Safety Regulations:

1.1. Please read the instruction manual carefully before operating this equipment for the first time. 

1.2. Please observe the safety and warning regulations! 

1.3. Failure to observe these regulations will exempt the manufacturer of all liability. 

1.4. Keep the operating instructions in a safe place. 

1.5. Failure to comply with the safety instructions and warnings can lead to serious injury or death of persons. 

Lance Lab Ltd

C2 Strangford Park

Ards Business Centre

Jubilee Road

Newtownards

BT23 4YH

United Kingdom

T: (0)28 9181 8313

E: [email protected]

W: www.lancelab.com

Summary of Contents for 8 m Telescopic Lance Series

Page 1: ...pray Nozzle Kit is available for Liquid Spraying Description Allows precision dusting at height Lance has a working height of 1 5m to 8m Reduces treatment time Reduces the need for access equipment Re...

Page 2: ...tions 6 Assembly instructions 7 Assembly instructions 8 Prolonging your lance s life 9 Maintenance 10 Maintenance 11 Maintenance 12 Troubleshooting 13 Troubleshooting 14 Lance Lab Ltd C2 Strangford Pa...

Page 3: ...bolare 4 1 5 Rohrsegment 5 Tube section 5 Segment de tube 5 Sezione tubolare 5 1 6 Rohrsegment 6 Tube section 6 Segment de tube 6 Sezione tubolare 6 1 7 Rohrsegment 7 Tube section 7 Segment de tube 7...

Page 4: ...t the user s own risk Should you have any doubts in this respect please contact the distributor where you purchased your product 4 2 The lance must not be used with oil substances caustic substances e...

Page 5: ...g on each end before use and the dust plug is in place correctly after use To release dust plug hose from the push fit connector press down the tab whilst doing this pull the plug hose to remove from...

Page 6: ...w black connector into sprayer trigger then connect the tubing to the push fit connector from top section of the lance 7 Remove the dust cap from the flexi tip then extend the flexi tip and lock in pl...

Page 7: ...XL 8 D a XL 8 D max 3 bar 3 m 9 When dusting ensure duster is pressurised to 3 bar to ensure efficient product application Dust blockages can occur from low pressures usage Bar pressures up to 6 bar c...

Page 8: ...pulling before use and the dust cap is in place correctly after use To release a liquid nozzle from the flexi tip remove the retainer clip and press the in tab whilst doing this pull the liquid nozzl...

Page 9: ...rry case 2 Do not scratch hard objects against the XL 8 3 The product should be cleaned with a soft dry cloth only Do not use volatile substances or cleaning products as these can cause damage Tips fo...

Page 10: ...ap and gasket with a pulling motion and save for reuse 4 Remove the push fit connector and save for reuse 3 Pull the broken flexi tip through the top section 7 5 Straighten the replacement flexi tip a...

Page 11: ...nd re attach the push fit connector to the flexi tip tubing and refit the dust plug For detailed videos on the maintenance process see www lancelab com 8 Insert the top section 7 back into the lance R...

Page 12: ...g tool is inserted at least 1 cm onto the flexi tip the threaded end cap dust caps removed and the open end pointing away from all persons To clear a hose kit connect to the push fit connector and con...

Page 13: ...he push fit connector and tap on a hard surface to dislodge trapped dust or rinse under hot running water and allow to dry then re fit to XL 8 lance See assembly instructions on page 5 There is a dust...

Page 14: ...rence Replacement Component Description Birchmeier Artikel Nr 1 XL 8 D Telescopic Lance 7 m Dust Version 119 354 01 2 Heavy Duty Carry Case 119 361 01 3 Flexible tip 119 362 01 4 8 m Hose Kit 119 363...

Page 15: ...H www lancelab com 028 9181 8313 Flexible stay put 54cm nozzle tube Compact tough and light allowing precision dusting Easily bent to allow access to restricted areas Attaches to a 1 5m dusting lance...

Page 16: ...a working height of 1 5m to 8m and reduces treatment time and the need for access equipment ensuring compliance with work at height regulations Operating Pressure Up to 3 bar dusting Max 6 bar liquid...

Reviews: