13
Ground source heat pumps since 1983
Use the browser button to move the cursor to “Heating curve”.
Press OK.
Press OK. Use keys – or + to set the value for the output water when the outdoor tempe-
rature is -20°C. Press OK.
Press OK. Use keys – or + to set the value for the output water when the outdoor tempe-
rature is 0°C. Press OK.
Press OK. Use keys – or + to set the value for the output water when the outdoor tempe-
rature is +20°C. Press OK.
Press ESC to exit.
3.1.2. Settings
The Lämpöässä regulator is controlled using set values. The available set values depend
on the sensor connections and geothermal heating options. Browsing the set values and
changing them is done as follows:
Press ESC until the display no longer changes. You are in the ‘Selection’ display.
Press OK. You can move from one regulating circuit to another using the browser button.
Use the browser button to move the cursor to “Settings”. Press OK.
Changing the set values for the heating regulation circuit:
Use the browser button to move the cursor to the setting you wish to change.
Press OK.
Use keys - and + to change the value.
Press OK.
Press ESC to exit.