© Lampert Werktechnik GmbH
2013
8
TOUCHSCREEN
(29)
Welding program (depending on user level)
(30)
Scroll within the selected user level
(31)
Pulse duration scale in milliseconds (ms)
(32) Output scale as a percentage (%)
(33)
Indicator
(34)
Pulse duration in milliseconds (ms)
(35)
Welding output as %
(36)
Preselect welding situation and pulse shape
(depending on user level)
(37)
Foot switch display (optional)
(38) Recommended setting range
5.2 EXPLANATION / OVERVIEW OF MENUS
(Fig. Schematic diagram of user levels)
ONCE IT IS SWITCHED ON, THE PUK D2 STARTS UP IN ITS START LEVEL (MAIN MENU).THE FOLLOWING USER
LEVELS CAN BE NAVIGATED AFTER PRESSING THE POWER REGULATOR (26):
a)
Start level (main menu):
Preselection of the material to be welded and
preselection of the welding situation with display of the
recommended settings range for welding power and
pulse duration
b) Custom programs
c) Retention welding
d) Fixation welding
e) Settings