Manual
Weather Sensor EOLOS-IND Modbus
(1643) EOLOS-IND Modbus
Manual
6.5
Measured Value and Parameter Register
The register range 30001 to 35000 of the Lambrecht sensors is intended for measured values.
The following measured values are provided by the EOLOS sensor.
Register
address
Parameter Name
Unit
Factor
Description
30001
Wind speed instantaneous value
m/s
10
1 decimal place
INT
30002
Wind speed mean value since last retrieval
m/s
10
1 decimal place
INT
30003
Wind speed maximum value
m/s
10
1 decimal place
INT
30004
Wind speed minimum value
m/s
10
1 decimal place
INT
30201
Wind direction instantaneous value
°
10
1 decimal place
INT
30202
Wind direction mean value since last retrieval °
10
1 decimal place
INT
30203
Wind direction maximum value
°
10
1 decimal place
INT
30204
Wind direction minimum value
10
1 decimal place
INT
30401
Air temperature instantaneous value
°C
10
1 decimal place
INT
30402
Air temperature mean value since last retrieval °C
10
1 decimal place
INT
30403
Air temperature maximum value
°C
10
1 decimal place
INT
30404
Air temperature minimum value
°C
10
1 decimal place
INT
30601
Humidity instantaneous value
% r.h.
10
1 decimal place
INT
30602
Humidity mean value since last retrieval
% r.h.
10
1 decimal place
INT
30603
Humidity maximum value
% r.h.
10
1 decimal place
INT
30604
Humidity minimum value
% r.h.
10
1 decimal place
INT
30701
Dew point instantaneous value
°C
10
1 decimal place
INT
30702
Dew point mean value since last retrieval
°C
10
1 decimal place
INT
30703
Dew point maximum value
°C
10
1 decimal place
INT
30704
Dew point minimum value
°C
10
1 decimal place
INT
30801
Air pressure instantaneous value
hPa
10
1 decimal place
INT
30802
Air pressure mean value since last retrieval
hPa
10
1 decimal place
INT
30803
Air pressure maximum value
hPa
10
1 decimal place
INT
30804
Air pressure minimum value
hPa
10
1 decimal place
INT
The registers addresses 30001 to 35000 apply to all LAMBRECHT meteo Modbus sensors, but are only available or valid if
the respective sensor supports the corresponding values. (e.g. a pure wind sensor does not provide any air humidity).
As error code or invalid value the LAMBRECHT sensors return 0xD8F1 (0xFF676981).
Note:
For each measurement type, the values from the registers with the maximum values (3XXX3) and minimum values
(3XXX4) are automatically reset as soon as the register with the mean values (3XXX2) has been read out. For example, reading
30402 resets registers 30403 and 30404.
9