Weather Sensor EOLOS-IND Modbus 

(1643) EOLOS-IND Modbus 

  

 

      Manual

6.5 

Measured Value and Parameter Register

The register range 30001 to 35000 of the Lambrecht sensors is intended for measured values. 

The following measured values are provided by the EOLOS sensor.

Register 
address

Parameter Name 

Unit

Factor

Description

30001

Wind speed instantaneous value

m/s

10

1 decimal place

INT

30002

Wind speed mean value since last retrieval

m/s

10

1 decimal place

INT

30003

Wind speed maximum value

m/s

10

1 decimal place

INT

30004

Wind speed minimum value

m/s

10

1 decimal place

INT

30201

Wind direction instantaneous value

°

10

1 decimal place

INT

30202

Wind direction mean value since last retrieval °

10

1 decimal place

INT

30203

Wind direction maximum value

°

10

1 decimal place

INT

30204

Wind direction minimum value

10

1 decimal place

INT

30401

Air temperature instantaneous value

°C

10

1 decimal place

INT

30402

Air temperature mean value since last retrieval °C

10

1 decimal place

INT

30403

Air temperature maximum value

°C

10

1 decimal place

INT

30404

Air temperature minimum value

°C

10

1 decimal place

INT

30601

Humidity instantaneous value

% r.h.

10

1 decimal place

INT

30602

Humidity mean value since last retrieval

% r.h.

10

1 decimal place

INT

30603

Humidity maximum value

% r.h.

10

1 decimal place

INT

30604

Humidity minimum value

% r.h.

10

1 decimal place

INT

30701

Dew point instantaneous value

°C

10

1 decimal place

INT

30702

Dew point mean value since last retrieval

°C

10

1 decimal place

INT

30703

Dew point maximum value

°C

10

1 decimal place

INT

30704

Dew point minimum value

°C

10

1 decimal place

INT

30801

Air pressure instantaneous value

hPa

10

1 decimal place

INT

30802

Air pressure mean value since last retrieval

hPa

10

1 decimal place

INT

30803

Air pressure maximum value

hPa

10

1 decimal place

INT

30804

Air pressure minimum value

hPa

10

1 decimal place

INT

The registers addresses 30001 to 35000 apply to all LAMBRECHT meteo Modbus sensors, but are only available or valid if 
the respective sensor supports the corresponding values. (e.g. a pure wind sensor does not provide any air humidity).

As error code or invalid value the LAMBRECHT sensors return 0xD8F1 (0xFF676981). 

Note: 

For each measurement type, the values from the registers with the maximum values (3XXX3) and minimum values 

(3XXX4) are automatically reset as soon as the register with the mean values (3XXX2) has been read out. For example, reading 
30402 resets registers 30403 and 30404.

9

Summary of Contents for EOLOS-IND

Page 1: ...egrated overvoltage protection Simple space saving assembly on 50 mm standard pipe The Perfect Weather Sensor For industrial use as well as under extreme environmen tal conditions 5 1 1 parameters in...

Page 2: ...Mounting 2 7 1 North Alignment of Wind Sensor 2 7 2 Power and Signal Connection 2 7 3 Safety Regulations 3 Maintenance 3 1 Regular Maintenance and Calibration 3 2 Visual Check and Cleaning 4 Transport...

Page 3: ...is method Lightweight mass and immovable measuring elements to enable very low starting values distance and attenuation constants as well as a very high repetition accuracy The sensor can be installed...

Page 4: ...t the mast if available If needed you can turn in or unscrew the pin by means of allen key 2 7 1 North Alignment of Wind Sensor For wind direction measurements the north mark on the sen sor must be al...

Page 5: ...signal of the sensor corresponds to the RS 485 standard The signal levels allow transmission via shielded signal cables up to a maximum length of 1 200 meters or 4 000 feet The cable lengths depend o...

Page 6: ...ngsscraube M8 fastening screw Erdscraube M6 earthing screw 10 1 5 6 0 1 P40 min P50 P48 3 5 6 0 1 10 1 min 40 P40 min 50 9 P 0 1 Aufnahmerohr f r den Sensor sensor seat pipe N Schlitz im Mastende baus...

Page 7: ...ensor EOLOS IND Modbus 1643 EOLOS IND Modbus Manual 7 IN 24 V DC f r Elektronik for electronic Schirm shield Erde earth 287 56 0RGEXV 578 1 2 3 4 1 2 3 4 br wt bl bk PIN color 5 5 N A br ws bl sw Farb...

Page 8: ...is transmitted in the order 0x12 0x34 Example big endian 32 bit or 64 bit Register size value 32 bits 0x12345678 is transmitted in the order 0x12 0x34 0x56 0x78 6 2 Device Address The addresses 1 247...

Page 9: ...stantaneous value r h 10 1 decimal place INT 30602 Humidity mean value since last retrieval r h 10 1 decimal place INT 30603 Humidity maximum value r h 10 1 decimal place INT 30604 Humidity minimum va...

Page 10: ...HT meteo o er the possibility of autocon guration This is supported e g by the data logger met LOG For autocon guration the register addresses of the measured values and sensor data available in the r...

Page 11: ...imal places LONG 0x04 Big Endian WORD 31102 Precipitation amount total Low WORD 3 decimal places Registers 31101 31102 can only be read out together function code 0x04 0x04 Big Endian WORD 31201 Preci...

Page 12: ...s 1 Dew point maximum value INT 46020 30703 Register address 1 Dew point minimum value INT 46021 30801 Register address 1 Air pressure instantaneous value INT 46022 30802 Register address 1 Air pressu...

Page 13: ...100 r h Parameters Wind direction Measuring range 0 360 Accuracy 3 RMS Resolution 1 Wind speed Measuring range 0 1 50 m s Accuracy 0 5 m s 5 RMS of the meas value at 5 1 40 m s Resolution 0 1 m s Air...

Reviews: