Lambrecht EOLOS-IND Manual Download Page 4

Manual
Weather Sensor EOLOS-IND Modbus 

(1643) EOLOS-IND Modbus 

  

 

      Manual 

2.5.1 

Power Input

The power input of the EOLOS reaches its peak in the start-up 
period (activation phase). The maximum of the power input 
is 2.5 A. In normal operation the average power input is sig-
nifi cantly lower (see table). The power input mainly depends 
on the fl ow rate. 

Wind speed

Ø Power input

0 m/s

500 mA

5 m/s

650 mA

20 m/s

900 mA

38 m/s

1100 mA

Measured at supply voltage of 24 VDC and 20 °C

2.5.2 

Protection

Generally it is not necessary to protect the secondary side 
(24 VDC) of the EOLOS. Normally only the primary side has 
to be protected. Nevertheless if the supply should be protected  
especially we recommend using a micro-fuse 3.15 A - medium 
time-lag. 

2.6 

Installation Procedure   

 

(Short Instruction)

The installation of the sensor involves 3 steps:

(1)  Mounting the cable at the sensor and if necessary 

draw the cable through the mast.

(2)  Mounting  the  sensor  at  the  mast,  but  before 

tightening the screws you must align the sensor to 
the north.

(3)  Attaching the cable to the power supply and the 

signal acquisition system.

2.7 

Mounting

The sensor can be installed on a standard pipe with an outer 
diameter of 50 mm and an inner diameter of maximum 40 mm. 
Before tightening the two 8 mm socket screws and attaching 
the sensor you have to draw the cable through the pipe and 
align the sensor into driving direction.
For this purpose the housing is marked accordingly (see draw-
ing). Before the screws of the sensor are tightened, the sensor 
is adjusted to north. Please pay attention to a fi rm mounting 
of the sensor at the mast!
In addition the sensor has a pin for the north direction. You can 
put this pin into the nick at the mast (if available). If needed 
you can turn in or unscrew the pin by means of allen key.

2.7.1 

North Alignment of Wind  

 

Sensor

For wind direction measurements the north mark on the sen-
sor must be aligned with the geographical north direction.
To adjust the wind sensor in a fi rm and correct manner into 
the north direction this item is equipped with an integrated 
mounting aid. Inside the inner bottom of the sensor a small bolt 

The place of installation should not be in the 
operation 

fi

 elds of radar devices (radar scanners 

or radar transmitters), generators or antennas. We 
recommend a minimum distance of 2 m to these 
installations. Furthermore a minimum distance of 
5 m to MF-/ HF- and Satcom- (e. g. Inmatsat, VSat) 
antennas has to be kept. The maximum electric 

fi

 eld 

intensity may not exceed 10 V/m (tested according to 
EMC standard). When indicated a greater distance 
should be kept. 

To avoid possible measurement errors due to heat sources as 
hot or warm fumes, hot surfaces etc. next to the sensor, the 
mounting site should be chosen accordingly.

2.2 

Tools and Installation Aids

There are no special tools or materials required for the instal-
lation works. All work can be carried out with standard tools 
available in a regular workshop. 

2.3 

Unpacking the Sensor

The sensor is packed in a separate box, carefully protected 
against mechanical infl uences during transport. 
Please verify that the following parts and documents are 
enclosed:
· 1 sensor EOLOS-IND Modbus
· 1 operating manual
Accessories: (depending on order size, in all cases separately 
packed)
Connecting cable with plug and core cable ends

2.4 

Goods Inspection

Please thoroughly check the delivery with regard to complete-
ness and eventual transport damages. In case of eventual 
claims please contact us in writing immediately. 

2.5 

Power Supply

The sensor requires at the input connector a 24 VDC nominal 
power source for operation.

4

Summary of Contents for EOLOS-IND

Page 1: ...egrated overvoltage protection Simple space saving assembly on 50 mm standard pipe The Perfect Weather Sensor For industrial use as well as under extreme environmen tal conditions 5 1 1 parameters in...

Page 2: ...Mounting 2 7 1 North Alignment of Wind Sensor 2 7 2 Power and Signal Connection 2 7 3 Safety Regulations 3 Maintenance 3 1 Regular Maintenance and Calibration 3 2 Visual Check and Cleaning 4 Transport...

Page 3: ...is method Lightweight mass and immovable measuring elements to enable very low starting values distance and attenuation constants as well as a very high repetition accuracy The sensor can be installed...

Page 4: ...t the mast if available If needed you can turn in or unscrew the pin by means of allen key 2 7 1 North Alignment of Wind Sensor For wind direction measurements the north mark on the sen sor must be al...

Page 5: ...signal of the sensor corresponds to the RS 485 standard The signal levels allow transmission via shielded signal cables up to a maximum length of 1 200 meters or 4 000 feet The cable lengths depend o...

Page 6: ...ngsscraube M8 fastening screw Erdscraube M6 earthing screw 10 1 5 6 0 1 P40 min P50 P48 3 5 6 0 1 10 1 min 40 P40 min 50 9 P 0 1 Aufnahmerohr f r den Sensor sensor seat pipe N Schlitz im Mastende baus...

Page 7: ...ensor EOLOS IND Modbus 1643 EOLOS IND Modbus Manual 7 IN 24 V DC f r Elektronik for electronic Schirm shield Erde earth 287 56 0RGEXV 578 1 2 3 4 1 2 3 4 br wt bl bk PIN color 5 5 N A br ws bl sw Farb...

Page 8: ...is transmitted in the order 0x12 0x34 Example big endian 32 bit or 64 bit Register size value 32 bits 0x12345678 is transmitted in the order 0x12 0x34 0x56 0x78 6 2 Device Address The addresses 1 247...

Page 9: ...stantaneous value r h 10 1 decimal place INT 30602 Humidity mean value since last retrieval r h 10 1 decimal place INT 30603 Humidity maximum value r h 10 1 decimal place INT 30604 Humidity minimum va...

Page 10: ...HT meteo o er the possibility of autocon guration This is supported e g by the data logger met LOG For autocon guration the register addresses of the measured values and sensor data available in the r...

Page 11: ...imal places LONG 0x04 Big Endian WORD 31102 Precipitation amount total Low WORD 3 decimal places Registers 31101 31102 can only be read out together function code 0x04 0x04 Big Endian WORD 31201 Preci...

Page 12: ...s 1 Dew point maximum value INT 46020 30703 Register address 1 Dew point minimum value INT 46021 30801 Register address 1 Air pressure instantaneous value INT 46022 30802 Register address 1 Air pressu...

Page 13: ...100 r h Parameters Wind direction Measuring range 0 360 Accuracy 3 RMS Resolution 1 Wind speed Measuring range 0 1 50 m s Accuracy 0 5 m s 5 RMS of the meas value at 5 1 40 m s Resolution 0 1 m s Air...