5
Operating Instructions
Precipitation Sensors (15188++)
(15188++) Precipitation Sensors
Operating Instructions
Connecting diagram with heating
Connecting diagram without heating
Basic settings - fig. 5
Unless otherwise agreed the precipitation sensor (15188++)
will be delivered with following basic settings:
· Active pulse output:
linearised • bounce-free signal
· Measuring range:
0...10 mm
· Active analog output:
0...20 mA
· Analog output of the absolute sum of precipitation
· Current consumption:
≤
40 mA
· Supply voltage:
18...30 V
DC
•
max. load 600
Ω
Fig. 4
Fig. 5
Fig. 6