8
Operating Instructions
Precipitation Sensors (15188++)
(15188++) Precipitation Sensors
Operating Instructions
Example 4 (Fig. 12): Low Power Mode - 2 wire circuit
·
Deactivated analog output
·
Active pulse output:
linearised • bounce-free signal
·
Current consumpt.:
max. 100
μ
A · typical 50
μ
m
·
Supply voltage:
5...30 V
DC
Example 5 (Fig. 13): Low Power Mode - PLC Interface
·
Deactivated analog output
·
Active pulse output:
linearised • bounce-free signal
·
Current consumpt.:
max. 100
μ
A · typical 50
μ
m
·
Supply voltage:
5...30 V
DC
Fig. 12
Fig. 13