Operating Instructions
Precipitation Sensors (15188++)

(15188++) Precipitation Sensors

Operating Instructions

Quality System certified by DQS according to
DIN EN ISO 9001:2000 Reg. No. 003748 QM

15188++ST3_b-de.pmd

27.09

Wilh. LAMBRECHT GmbH
Friedländer Weg 65-67
37085 Göttingen
Germany

Tel

+49-(0)551-4958-0

Fax

+49-(0)551-4958-312

E-Mail

[email protected]

Internet

www.lambrecht.net

Subject to change without notice.

Technical data

(15188++) Variety with 2 cm

bucket, unheated

Id-No.

00.15188.002 050

Measuring principle Weighing tipping bucket designed

acc. to Joss-Tognini

Range of application 0...+70°C - measuring
Measuring range

2 cm³ (2 g water) - volume of bucket
0...10 mm/ min

Resolution

0.1 mm

Accuracy

± 2%

Dimensions

See dimensional drawing

Suitable for mounting Ø 60 mm
Weight

Approx. 4 kg

Standards

WMO-No. 8 • VDI 3786 Bl. 7
EN 50081/82 • VDE 0100

Analog outputs:

0...20 mA = basic setting
4...20 mA • 0...5/10 V - selectable

Current consump.

≤ 

40 mA

Supply voltage

18...30 V

DC

 • max. load 600 

Ω

Pulse output for linearised, bounce-free output signal

At deactivated analog output:

Current consump.

Max. 100 

μ

A · typical 50 

μ

A

Supply voltage

5...30 V

DC

Switch load

Max. 30 V

DC

/ max. 0.5 A - at pure ohm

load

(15188 H++) Variety with 2 cm

3

 bucket, heated

Data like (15188++) 00.15188.002 050, but in additional with
controlled 2-circuit-heating:

Id-No.

00.15188.202 050

Heating data

Electronic controlled, dual-circuit

Accuracy

4°C ± 2°C, controlled temperature
within a range of -20...+4°C

Heating power

100 W (funnel)
70 W  (outlet/ tipping bucket)

Supply voltage

42 V

AC

Range of application -30...+70°C (no icing, no snowdrift)

(15188 W4++) Variety with 4 cm

bucket, unheated

Data like (15188++), but for very high precipitation intensity

Id-No.

00.15188.004 050

Measuring range

4 cm³ (4 g water) - volume of bucket
0...20 mm/ min

Resolution

0.2 mm

(15188 H W4) Variety with 4 cm

3

 bucket, heated

Date like (15188 W4++) 00.15188.004 050, but in additional
with controlled 2-circuit-heating, like (15188 H)

Id-No.

00.15188.204 050

Safety instructions

This system is designed according to the state-of-the-art ac-
cepted safety regulations. However, please note the following
rules:
1. Before setting into operation, please read all appropriate

manuals!

2. Please take notice of internal and state-specific guidelines

and/or rules for the prevention of accidents (e.g. the pro-
fessional association). If necessary ask your responsible
safety representative.

3. Use the system according to the manual’s regulations only.

4. Always leave the manual at hand at the place of work of

the system.

5. Use the system in technically correct conditions only! You

have to eliminate influences immediately, which impair the
security .

6. Please note the loss of warranty and non-liability by unau-

thorized manipulation of the system. You need a written
permission of the Wilh. LAMBRECHT GmbH for changes
of system components. These activities must be operat-
ed by a qualified technician.

7. Prevent the ingress of liquids into the devices without per-

mission.

General accessories

32.15188.061 090

(15188 U61i) Connecting cable (4-core)
sensor/ data logger, L = 7 m

00.15180.400 000

(1518 S4) Stainless steel mast for
concrete foundation

00.15180.800 000

(1518 S8) Stainless steel mast for
concrete foundation with base plate

32.15180.021 010

(1518 U21a) Bird protection ring

33.15180.049 000

(1518-49) Dirt pan (spare part)

For varieties with heating

32.15188.061 090

(15188 U61i) Connecting cable (4-core)
sensor/ data logger, L = 7 m

00.15123.242 000

(15123) Filament transformer

32.15188.060 060

(15188 U60f) Connecting cable (2-core)
sensor/ filament transformer; L=

1

 m

00.15180.400 010

(1518 S4a) Stainless steel mast for
concrete foundation with support for
the filament transformer

00.15180.800 030

(1518 S8c) Stainless steel mast for
concrete foundation with base plate and
support for the filament transformer

Services 

(see page 6):

97.15180.000 000

User-specific configuration of the
precipitation sensor

Summary of Contents for 15188++

Page 1: ... as absolute or gliding sum for the analogue output signals Exchangeable weighing tipping bucket system according to Joss Tognini overflow proof 2 cm tipping bucket 2g water for precise precipitation mea suring in regions with normal rain falls 4 cm tipping bucket 4g water for precise precipitation mea suring in regions with heavy rain falls tropical rain Winter fit variety with controlled 2 circu...

Page 2: ...of water The collecting surface of 200 cm WMO standard means that one bucket charge is equivalent to a precipita tion rate of 0 1 mm resp 0 2 mm per square meter If the bucket is tipped the reed contact that is integrated in the sensor will be closed This signal can be sent as pulse or analog The bounce free linearised pulse output is permanently available parallel to an analog current or voltage ...

Page 3: ... fitting the tipping bucket proceed with utmost caution so that the sharp edges of the tipping bucket are not damaged and the middle wall is not bent During operation the tipping bucket lies on the precision buck et bearings To reduce the friction which is produced at one tipping the bearings are made of abrasion resistant delrin The mounted tipping bucket is secured against eventual changes of po...

Page 4: ...ge red heating on Initial operation If the sensor system has been completely mounted and elec trically assembled the sensor will be ready for operation according to the basic settings The operational check has to be performed Maintenance and operational check The precipitation sensor 15188 is nearly mainte nance free The sensor should be checked and cleaned periodically in order to guarantee its p...

Page 5: ...ating Basic settings fig 5 Unless otherwise agreed the precipitation sensor 15188 will be delivered with following basic settings Active pulse output linearised bounce free signal Measuring range 0 10 mm Active analog output 0 20 mA Analog output of the absolute sum of precipitation Current consumption 40 mA Supply voltage 18 30 VDC max load 600 Ω Fig 4 Fig 5 Fig 6 ...

Page 6: ...rs See also tab 1 J3 to select the required mode Pos 1 8 J4 J5 to switch on the respective analog output J6 to switch over the analog voltage output J12 to connect the switch output to the power supply for 2 wire circuit of the low power modi not plugged pow er supply and pulse output are separated J10 must be plugged always at the middle position see fig 14 Fig 8 Positions of the jumpers which ar...

Page 7: ...n Sensors Operating Instructions Fig 9 Fig 10 Fig 11 Example 1 Fig 9 Active analog output 4 20 mA otherwise like basic setting Example 2 Fig 10 Active analog output 0 5 V otherwise like basic setting Example 3 Fig 11 Active analog output 0 10 V otherwise like basic setting ...

Page 8: ...cuit Deactivated analog output Active pulse output linearised bounce free signal Current consumpt max 100 μA typical 50 μm Supply voltage 5 30 VDC Example 5 Fig 13 Low Power Mode PLC Interface Deactivated analog output Active pulse output linearised bounce free signal Current consumpt max 100 μA typical 50 μm Supply voltage 5 30 VDC Fig 12 Fig 13 ...

Page 9: ...d range At exceeding of this final value a new summation starts i e the analog signal starts again on the low level saw tooth diagram 3 Gliding sum of precipitation At this operating mode the accumulated amount of precipita tion which is updated each minute is emitted within the se lected time frame At exceeding the final value of the selected range the analog signal remains on the highest level u...

Page 10: ...00 15188 004 050 but in additional with controlled 2 circuit heating like 15188 H Id No 00 15188 204 050 Safety instructions This system is designed according to the state of the art ac cepted safety regulations However please note the following rules 1 Before setting into operation please read all appropriate manuals 2 Please take notice of internal and state specific guidelines and or rules for ...

Reviews: