INOX TECH 45 H
20
EN
cod. 3541R890RU - Rev. 00 - 04/2019
Table. 6 - Accessories
Connection to collective flues
fig. 20 - Examples of connection to collective flues (
= Air /
= Fumes)
Table. 7 - Typology
If the boiler is to be connected
INOX TECH 45 H
to a collective flue or to a single flue
with natural draught, the flue or chimney must be expressly designed by professionally
qualified technical personnel in conformity with the current regulations and be suitable
for sealed chamber units equipped with fan.
3.7 Condensate drain connection
IMPORTANT
The boiler has an internal trap for draining condensate. Install the inspection union
“A”
and hose
“B”
by press fitting. Before commissioning, fill the trap with approx. 0.5 L of
water and connect the hose to the disposal system.
B
ATTENTION: THE UNIT MUST NEVER BE OPERATED WITH THE TRAP
EMPTY!
OTHERWISE THERE IS A DANGER OF SUFFOCATION DUE TO THE EMIS-
SION OF THE COMBUSTION FUMES.
fig. 21 - Condensate outlet connection
4. SERVICE AND MAINTENANCE
4.1 Adjustments
Gas conversion
The unit can operate on Natural Gas or LPG and is factory-set for use with one of these
two gases, as clearly shown on the packing and on the data plate. Whenever a different
gas to that for which the unit is arranged has to be used, a conversion kit will be required,
proceeding as follows:
1.
Remove the front panel (
see *** 'Opening the front panel' on page 21 ***
).
2.
Undo the screw and rotate the control panel (see fig. 22).
3.
Unscrew ring
C
and remove gas pipe
A
from the gas valve (see fig. 23).
4.
Replace nozzle
B
inserted in the gas pipe with that contained in the conversion kit,
interposing seal
D
(see fig. 23).
5.
Refit gas pipe
A
and check the tightness of the connection.
6.
Apply the label, contained in the conversion kit, near the data plate.
7.
Refit the front panel.
8.
Modify the parameter for the type of gas
:
•
put the boiler in standby mode
•
press the
DHW
buttons details 1 and 2 - fig. 1 for 10 seconds: the display shows
“b01”
flashing.
•
press the
DHW
buttons details 1 or 2 - fig. 1 to set parameter
00
(for operation
with natural gas) or
01
(for operation with LPG).
•
press the
h
button (detail 4 - fig. 1until
“b04”
flashes on the display.
•
press the
DHW
buttons (details 1 or 2 - fig. 1) to set parameter
200
(for opera-
tion with natural gas) or
190
(for operation with LPG).
•
press the
h
button (detail 4 - fig. 1) until
“b05”
flashes on the display
•
press the
DHW
buttons details 1 or 2 - fig. 1 to set parameter
200
(for operation
with natural gas) or
190
(for operation with LPG).
•
press the
DHW
buttons details 1 and 2 - fig. 1 for 10 seconds.
•
the boiler will return to standby mode
9.
Using a combustion analyser connected to the boiler fume outlet, check that the
CO
2
content in the fumes, with the boiler operating at max. and min. output, matches
that given in the technical data table for the corresponding type of gas.
Losses in m
eq
Air
inlet
Fume exhaust
Vertical
Horizontal
Ø 80
PIPE
1 m M/F
1KWMA83W
1.0
1.6
2.0
BEND
45° M/F
1KWMA65W
1.2
1.8
90° M/F
1KWMA01W
1,5
2.0
PIPE SECTION
with test point
1KWMA70W
0.3
0.3
TERMINAL
air, wall
1KWMA85A
2.0
-
fumes, wall with antiwind
1KWMA86A
-
5.0
FLUE
Split air/fumes 80/80
010027X0
-
12.0
Fume outlet only Ø80
01
1KWMA86U
-
4.0
Ø 60
PIPE
1 m M/F
1KWMA89W
6.0
BEND
90° M/F
1KWMA88W
4.5
REDUCTION
80/60
041050X0
5.0
TERMINAL
fumes, wall with antiwind
1KWMA90A
7.0
ATTENTION: CONSIDER THE HIGH PRESSURE LOSSES OF Ø60 ACCESSORIES;
USE THEM ONLY IF NECESSARY AND AT THE LAST FUME EXHAUST SECTION.
Type
Description
C2X
Intake and exhaust in common flue (intake and exhaust in same flue)
C4X
Intake and exhaust in common and separate flues, but undergoing similar wind conditions
C8X
Exhaust in single or common flue and wall intake
B3X
Intake from installation room by means of concentric duct (that encloses the exhaust) and exhaust in
common flue with natural draught
IMPORTANT- THE ROOM MUST BE PROVIDED WITH APPROPRIATE VENTILATION
C93
Exhaust to a vertical terminal and intake from existing flue.
C
8X
C
2X
C
4X
C
93
C
93
0,5lt
A
B