46
EN
Cod. 3541Z090 - Rev. 05 - 05/2022
IDOLA S 3.2
Menu
Level 1
Menu Level 2
Menu Level 3
Menu Level 4 Menu Level 5
Description
Lower
limit
Upper
limit
Resolu-
tion
Unit of
mea-
sure
Default
value
Operation
Param.
Online Un.Its N
UNIT ONLINE INFO
/
/
/
/
/
Operate Mode
Operating mode (Heat or Cool or Off)
0
3
1
/
/
Sv1 State
on/off
State of the 3-way valve SV1 (plant=off, DHW=on)
ON
OFF
/
/
/
Sv2 State
State of the 3-way valve SV2 (off=cool, on=heat)
ON
OFF
/
/
/
Sv3 State
State of the 3-way valve of zone 2 (mixing valve)
ON
OFF
/
/
/
Pump_I
State of the water pump of the unit
ON
OFF
/
/
/
Pump_O
State of the water pump of zone 1
ON
OFF
/
/
/
Pump_C
State of the water pumpe zone 2
ON
OFF
/
/
/
Pump_S
State of the solar water pump
ON
OFF
/
/
/
Pump_D
State of the DHW recirculation pump
ON
OFF
/
/
/
Pipe Bckp He
State of the backup heater IBH1
ON
OFF
/
/
/
Tank Bckp He
State of the DHW boiler el. heater TBH
ON
OFF
/
/
/
Gas Boiler
State of the gas boiler
ON
OFF
/
/
/
T1 Leav W Temp
Water temperature measured by probe T1
/
/
1
°C
/
Water Flow
Water flow rate (estimated)
/
/
0,001
m3/h
/
Heat Pump Cap
Heat pump capacity (estimated)
/
/
0,1
kW
/
T5 W. Tank
Water temperature measured by probe T5
/
/
1
°C
/
Tw2 Cir2 W. Temp.
Water temperature measured by probe Tw2
/
/
1
°C
/
T1S1 Cir1 Cli Temp
Water setpoint calculated by climatic curve for zone 1
/
/
1
°C
/
T1S2 Cir2 Cli Temp
Water setpoint calculated by climatic curve for zone 2
/
/
1
°C
/
Tw_O Plate Out Temp.
Water temperature measured by probe Tw_out
/
/
1
°C
/
Tw_I Plate Inl Temp.
Water temperature measured by probe Tw_in
/
/
1
°C
/
Tbt1 Buf Tank Up Temp.
Water temperature measured by probe Tbt1
/
/
1
°C
/
Tbt12 Buf Tank Low T.
not used
/
/
/
°C
/
Tsolar
Water temperature measured by probe Tsolar
/
/
1
°C
/
Idu Sw
IDU Software
/
/
/
/
/
Odu Model
ODU model
/
/
/
/
/
Compr Current
Compressor input current
/
/
1
A
/
Compr Freq
Compressor working frequency
/
/
1
Hz
/
Compr Run Time
Working time from the last start of the compressor
/
/
1
min
/
Compr Run Time Tot
Total workin time of the compressor
/
/
1
h
/
Exp Valve Open
Expansion valve opening steps
0
500
1
STEP
/
Fan Speed
Fan speed
0
650
10
RPM
/
Unit Target Freq.
Unit target frequency
/
/
1
Hz
/
Freq Lim Type
Frequency limiting scheme
/
/
/
/
/
Supply Voltage
Supply voltage
0
450
1
V
/
Dc Gener Voltage
DC bus voltage
0
255
1
V
/
Dc Gener Current
DC bus current
0
255
1
A
/
T2 Plate Gas Out T.
Water temperature measured by probe T2
/
/
1
°C
/
T2B Plate Gas In T.
Water temperature measured by probe T2B
/
/
1
°C
/
Th Comp Suc Temp
Water temperature measured by probe Th
/
/
1
°C
/
Tp Comp Disch Temp
Water temperature measured by probe Tp
/
/
1
°C
/
T3 Outd Exch Temp
Water temperature measured by probe T3
/
/
1
°C
/
T4 Outd Air Temp.
Water temperature measured by probe T4
/
/
1
°C
/
Tf Modul Temp
Water temperature measured by probe Tf
/
/
1
°C
/
P1 Compr H_Press
P1 high press compressor
0
5000
1
kPa
/
P2 Compr L_Press
P2 low press compressor
0
5000
1
kPa
/
Odu Sw Date
Outdoor unit SW date
/
/
/
/
/
Odu Sw Ver
Outdoor unit SW version
/
/
/
/
/
Idu Sw Date
Indoor unit SW date
/
/
/
/
/
Idu Sw Ver
Indoor unit SW version
/
/
/
/
/
For servi-
ceman
Password
Password to access to service menù
0
9999
1
/
/