UK
31
TECHNICAL FEATURES
M
PRESSURE CURVES
M
Model
EM 35-E
EM 40/2-E
EM 40/M-E
Methane delivery
min
5,5
12,2
12,2
m
3
/h
max
15,3
41,3
41,3
m
3
/h
B/P delivery
min
7
4,3
4,3
m
3
/h
max
12
14,7
14,7
m
3
/h
Thermal output
min
188
115
115
kW
max
320
390
390
kW
Motor
370
370
370
W
Transformer
12/35 - 15/40
kV/mA
Max. absorbed power
680
680
680
W
Methane pressure
20
mbar
B/P pressure
30
mbar
Weight
40
41
41
kg
Power supply
230V-50Hz (*) single-phase
Category
II 2H 3P
Electric protection rating
20
IP
Noise level (**)
75
75
75
dB(A)
(*) 60Hz operation only with electronic transformer.
(**) Sound pressure measured in the manufacturer’s combustion laboratory, with burner operating on a test boiler
and at maximum output.
The pressure curves indicate the output in kW according to the backpressure in the combu-
stion chamber, in mbar.
Thermal output (kW)
Combustion chamber pressure (mbar)