GENERAL
ENGLISH
PARAMETER PROGRAMMING
Simultaneously press the buttons P2 and P3 for 10s to access the programming menu where the left digit indicates the
parameter number, and the centre and right digits the parameter value.
When the programming menu has been accessed, the left digit will blink; use the P3 and P4 buttons to change the para-
meter number, and the P5 and P6 buttons to change the value which will immediately be stored.
While changing the parameter, the system will check that the permitted limits are not exceeded.
Parameters displayed:
1
Boiler model - 0 Fast with plates - 1 Bithermal - 2 Water heater - 3 Water heater
2 Gas type selection - 0 Natural gas - 1 LPG
3 Maximum heat output: Range 0-100% (preset to 100%)
4 Heating restart timing: Range 0-20 = tmin 0-10 (preset to 4 = 2 min)
5 Ignition power: Range 0-75% (preset to natural gas 40% and LPG 35%)
6 Heating temperature adjustment range (preset to 1=30 - 83°C). Range 0=30 - 45°C (floor heating)
7 Heating pump post-circulation time setting: Range 0-20 (0-10 minutes) (Preset to 4 = 2 minutes)
8 Anti-Legionella function activation with boiler/water heater: 1 active, 0 inactive (preset to 1)
9 Do not use. (parameter not handled “--”)
0 Water heater pump post-circulation time setting: Range 0-20 (0-10 minutes) (preset to 4=2 minutes).
To exit the menu, press the P1 button or wait 20s without pressing any button.