EN
cod. 3541V620 - Rev. 00 - 05/2021
ALHENA TECH H
* Restore Factory Values
To restore all the parameters to the factory values, set parameter
b29
to
10
and confirm. Turn the
power off for 10 seconds and then back on.
At this point it is necessary to return parameter
b02
to the correct value, according to the type of
boiler. Parameter
b27
will be automatically set to
5
.
Display Adjustment Menu [DISPLAY]
Here it is possible to set some display pa-
rameters.
[Contrast]
Contrast adjustment.
[Brightness]
Brightness adjustment
[Backlight time]
Display backlight duration.
[Reset]
Restore factory values.
fig. 40
P64
Fan maximum speed
DO NOT MODIFY
(The parameters are automatically updated)
G20/G230:
ALHENA TECH 28 H = 172
ALHENA TECH 34 H = 194
G30/G31:
ALHENA TECH 28 H = 156
ALHENA TECH 34 H = 186
P65
Not implemented
--
1
P66
Valve frequency
0 ÷ 2
1
P67
Installation C10/C11
0 - 1
0
P68
Flue parameter
0 ÷ 10 (modify according to flue table)
0
Index
Description
Range
Default
DISPLAY
Contrast
Brightness
Backlight time
Reset
4
Max
1m
Summary of Contents for ALHENA TECH 28 H
Page 45: ...45 IT cod 3541V620 Rev 00 05 2021 ALHENA TECH H fig 48 fig 49 fig 50 5 6 6 ...
Page 103: ...103 ES cod 3541V620 Rev 00 05 2021 ALHENA TECH H fig 48 fig 49 fig 50 5 6 6 ...
Page 160: ...160 RO cod 3541V620 Rev 00 05 2021 ALHENA TECH H fig 48 fig 49 fig 50 5 6 6 ...
Page 217: ...217 PL cod 3541V620 Rev 00 05 2021 ALHENA TECH H wygląd 48 wygląd 49 wygląd 50 5 6 6 ...
Page 275: ...275 EL cod 3541V620 Rev 00 05 2021 ALHENA TECH H İȚț 48 İȚț 49 İȚț 50 5 6 6 ...
Page 330: ...330 EN cod 3541V620 Rev 00 05 2021 ALHENA TECH H fig 48 fig 49 fig 50 5 6 6 ...
Page 343: ......