318
EN
cod. 3541V620 - Rev. 00 - 05/2021
ALHENA TECH H
B
After installation, check the tightness of the fumes and gas
circuit.
OTHERWISE THERE IS DANGER OF SUFFOCATION
DUE TO THE EMISSION OF COMBUSTION FUMES.
2.7 Condensate drain connection
IMPORTANT
The boiler has an internal trap for draining condensate. Install the hose
“B”
by pressing it into
place. Before commissioning, fill the trap with approx. 0.5 L of water and connect the hose to the
disposal system.
Drains connected to the drainage system must be resistant to acidic condensate.
If the condensate drain is not connected to the waste water drainage system, a neutralizer must
be installed.
B
ATTENTION: THE UNIT MUST NEVER BE OPERATED
WITH THE TRAP EMPTY!
OTHERWISE THERE IS A DANGER OF SUFFOCATION
DUE TO THE EMISSION OF COMBUSTION FUMES.
THE CONDENSATE DRAIN MUST BE CONNECTED
TO THE DRAINAGE SYSTEM IN SUCH A WAY THAT
THE LIQUID CONTAINED CANNOT FREEZE.
fig. 37- Condensate drain connection