11.

 

Functions and adjustments 

 

11.1.

 

Basic information about the menu navigation 

 

 

With only four keys you can adjust your heating controller or your heating system. With the keys you can get 
from the starting menu (an example is shown on the previous page) into every submenu to see the desired 
values of the heating system or to change them. Please consider, that values can only be changed at the 
remote control, if these values or dates are enabled for changing by the manufacturer. The display lightening 
is switched on automatically, if a key is pressed for the first time. The lightening is switched off 30 seconds 
after the last key has been pressed. 

 

 

Attention!  

 

The adjustments at the digital remote control have always priority to the adjustments at the heating 
controller! 

 

Please also consider the operating and the commissioning manual of the heating controller for all 
works and adjustments at your digital remote control. 

!

 

 

 

Basically: 

 

 

the key             acknowledges your choice 
(change of an operating mode, move to a sub-
menu, save a changed value) 

 

the key             deletes your choice (manual 
switchover, leave a submenu, delete an entered 
value) 

 

the keys             and              choose a submenu 
and change values of your heating system. To 
open the heating specialist level (operating level 
3) press the key             and             for 5 sec-
onds. 

 

 

11.2.

 

Move to a submenu 

 

 

The following submenus are available: 

 

AE 

– 

Setpoint values 

 

i  

– 

Information 

 

CH 

– 

Switching times  

 

Display of time and weekday 

 

Display of date (DD.MM.YY) 

 

 

To move from the starting display to a submenu, press the key             or             until the desired submenu is 
displayed. Acknowledge your choice with the key              . 

 

OK 

esc 

 

– 

 

– 

 

– 

OK 

Functions and adjustments 

Summary of Contents for DFW HZR

Page 1: ...Page 1 OPERATING AND COMMISSIONING MANUAL...

Page 2: ...cal connection of the remote control at the heating controller 5 9 Disassembly and disposal 6 10 Your digital remote control is structured like this 6 11 Functions and adjustments 7 11 1 Basic informa...

Page 3: ...t wall construction housing 1 2 Technical data Connection eBus max 24 V 50 mA DC 2wire connection pole independent Sensors NTC temperature sensors 8 2 k at 25 C Protection degree IP 20 according to DI...

Page 4: ...d liability All regulations about warranty and liability are defined in the general terms and conditions of the manufacturer or in the particular contractual relationship Warranty and liability claims...

Page 5: ...ply of the heating controller every time before the clamp cover is opened Make sure that the controller cannot be switched on DNAGER Connect the remote control to the heating controller Use a 2 wire w...

Page 6: ...lectronic equipment act or ElektroG 10 Your digital remote control is structured like this Your remote control has a clearly arranged display which indicates information e g about actual tempera tures...

Page 7: ...e always priority to the adjustments at the heating controller Please also consider the operating and the commissioning manual of the heating controller for all works and adjustments at your digital r...

Page 8: ...re During the data transfer adjustments via the keys are blocked That means you have to wait until the data transfer has been completed if you want to change values 11 5 Leave a submenu With the key y...

Page 9: ...0 3 Max 3 0 1 2 Steepness 2 heating circuit As steepness 1 heating circuit Only adjustable in configuration 5 or 6 No 2 Min 0 3 Max 3 0 1 2 P value 1 heating circuit Proportional range Only adjustable...

Page 10: ...ating mode day OFF or day night When adjusting this operating mode you are asked to enter a start date and an end date OFF Heating and hot water support are off Only hot water The hot water support ru...

Page 11: ...n the controller The cursor below the symbol of the adjusted operating mode flashes Manual change to tem perature regulation econ omy level In this mode you leave the automatic temperature regulation...

Page 12: ...ystem and its configuration which sensors are mounted at your heating system For this reason it is possible that your controller does not display all values that are shown in the following chart Comin...

Page 13: ...ction Factory setting Range Your setting 1 Controller address 1 1 8 2 Controller type only display 3 HZR C 2 HZR E 3 Controller configuration only display 1 8 E3 2 Correction value No Action Factory s...

Page 14: ...nformation on the display check if the device is connected correctly 3 Check if there is an error that is described in the commissioning manual of the heating controller Replace the digital remote con...

Page 15: ...Page 15 Notes...

Page 16: ...ng manual is not allowed to be duplicated distributed altered transferred and translated into another language or to be used otherwise The information in this oper ating and commissioning manual has b...

Reviews: